{"product_id":"tx2a0009kbkf","title":"TX2A0009KBKF - Hammond Power Solutions 3-Phase Encapsulated Transformer 9kVA 480D-208Y\/120V Copper 60Hz Type 4\/IP66","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eTX2A0009KBKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eTX2A0009KBKF\u003c\/b\u003e is a 3-phase encapsulated transformer from Hammond Power Solutions, designed for reliable power distribution in demanding environments. This transformer features a robust Type 4\/IP66 rated enclosure, making it suitable for harsh indoor or outdoor applications. The unit is built with copper windings and is engineered for efficient operation at 60Hz, providing a primary voltage of 480V delta and a secondary voltage of 208Y\/120V. The transformer is wall-mountable and includes a removable hinged door for easy access and maintenance. This Hammond Power Solutions Titan-X series transformer is encapsulated in epoxy and silica for superior protection against moisture, dust, and contaminants. It is seismically qualified according to IBC 2018 and ASCE 7-16 standards, with a spectral acceleration rating of SDS ≤2.0g and an importance factor of Ip = 1.5. The unit is also O.S.H.P.D. California Certified and meets NEMA ST-20 sound level requirements, operating at a quiet 45 dBA. The transformer is suitable for use in a wide range of industrial, commercial, and utility applications where durability and reliability are essential. \u003cul\u003e \u003cli\u003ePart Number: TX2A0009KBKF\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eSeries: Titan-X\u003c\/li\u003e \u003cli\u003eType: 3-Phase Encapsulated Transformer\u003c\/li\u003e \u003cli\u003ekVA Rating: 9kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 480V Delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 208Y\/120V\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eWinding Material: Copper\u003c\/li\u003e \u003cli\u003eEnclosure Rating: Type 4\/IP66\u003c\/li\u003e \u003cli\u003eMounting Type: Wall\u003c\/li\u003e \u003cli\u003eSeismic Qualification: IBC 2018, ASCE 7-16, SDS ≤2.0g, Ip = 1.5\u003c\/li\u003e \u003cli\u003eO.S.H.P.D. California Certified\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eDimensions: 14.69\" H × 19.13\" W × 11.88\" D\u003c\/li\u003e \u003cli\u003eFinish: ANSI 61 Grey\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: TX2A0009KBKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 208Y\/120\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 9\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 4 \/ IP66\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DQT3-N4\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 14.69in\/374mm(H), 19.13in\/486mm(W), 11.88in\/302mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 9\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423168377\u003c\/li\u003e\n\u003cli\u003eWeight : 194 \u003c\/li\u003e\n\u003cli\u003eCertification : ABS, ATEX, IECEx and UKEx (Class I, Zone 2, Group IIC, T3 Hazardous Location)\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/TX2A0009KBKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DQT3-N4\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62209320485023,"sku":"TX2A0009KBKF-New","price":2942.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/TX2A0009KBKF.jpg?v=1757546182","url":"https:\/\/essentialparts.com\/products\/tx2a0009kbkf","provider":"Essential Electric Supply","version":"1.0","type":"link"}