{"product_id":"tn2d0112kdkf","title":"Hammond Power Solutions TN2D0112KDKF - 3-Phase Transformer 112.5 kVA (480D-240D)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eTN2D0112KDKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions TN2D0112KDKF is a three-phase transformer designed for general duty applications including some hazardous locations and marine ABS duty. This 112.5 kVA unit operates at 480V delta primary to 240V delta secondary voltage with copper windings rated for 115Â°C temperature rise and 180Â°C insulation class. The transformer features a Type 4\/IP66 enclosure with ANSI 61 grey finish measuring 25.63 inches high by 36.63 inches wide by 30.75 inches deep, producing minimal 55 dBA operational noise. It meets OSHPD and IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) with 2-5% impedance and includes standard mounting pad terminations with 2x2.5% primary FCAN taps. Typical applications include industrial power distribution systems requiring reliable performance in demanding environments.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Three-phase general duty transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 480V delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 240V delta\u003c\/li\u003e \u003cli\u003ekVA Rating: 112.5 kVA\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eImpedance: 2-5% standard\u003c\/li\u003e \u003cli\u003eTemperature Rise: 115Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 4\/IP66, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 25.63\" H Ã— 36.63\" W Ã— 30.75\" D\u003c\/li\u003e \u003cli\u003eSound Level: 55 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: OSHPD, IBC 2018\u003c\/li\u003e \u003cli\u003eVector Configuration: Dd0 (0Â°)\u003c\/li\u003e \u003cli\u003ePrimary FCAN: 2x2.5%\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: TN2D0112KDKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 240D\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 112.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 55dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 4 \/ IP66\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 25.63in\/652mm(H), 36.63in\/931mm(W), 30.75in\/782mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 112.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dd0 (0Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Mounting Pads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423168308\u003c\/li\u003e\n\u003cli\u003eWeight : 5.19 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/TN2D0112KDKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DQT9-N4\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62209313407135,"sku":"TN2D0112KDKF-New","price":31520.98,"currency_code":"USD","in_stock":true}],"url":"https:\/\/essentialparts.com\/products\/tn2d0112kdkf","provider":"Essential Electric Supply","version":"1.0","type":"link"}