{"product_id":"sk3a1000pb3k","title":"SK3A1000PB3K - Hammond Power Solutions 1000 kVA 3-Phase 600V General Purpose Transformer Type 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSK3A1000PB3K\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eSK3A1000PB3K\u003c\/b\u003e is a 1000 kVA, 3-phase general purpose transformer from Hammond Power Solutions designed for low voltage distribution applications.\u003cp\u003eThis transformer is rated for 600 volts and below, suitable for powering appliances, lighting, heating, and motorized machine loads. It features a 208Y\/120V secondary voltage configuration, copper windings, and operates at 60 Hz frequency with a 150°C temperature rise insulation system. The enclosure is a heavy-duty ventilated Type 3R, providing protection against rain and snow, making it suitable for outdoor use. It is UL Listed and CSA Certified, meeting North American efficiency standards including U.S. DOE 10 CFR Part 431 and Canadian NRCan regulations. The design includes front accessible separate high and low voltage terminals compatible with copper and aluminum conductors. This model is part of the HPS Sentinel series known for energy efficiency and reliability.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 1000 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 600 V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 208Y\/120 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eInsulation System: 150°C rise, 220°C class\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: Heavy duty ventilated Type 3R\u003c\/li\u003e\n\u003cli\u003eWinding Material: Copper\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003cli\u003eMounting Type: Floor mount standard, wall mount optional\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SK3A1000PB3K\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 600D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 208Y\/120\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 1358.31\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=0, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 67 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 4% - 7.5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 72in\/1829mm(H), 54in\/1372mm(W), 44in\/1118mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 1000\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=0\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Mounting Pads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPC : 803423130497\u003c\/li\u003e\n\u003cli\u003eWeight : 1600 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SK3A1000PB3K\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH7-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/ul\u003e","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62209105133727,"sku":"SK3A1000PB3K-New","price":78564.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SK3A1000PB3K.jpg?v=1757545244","url":"https:\/\/essentialparts.com\/products\/sk3a1000pb3k","provider":"Essential Electric Supply","version":"1.0","type":"link"}