{"product_id":"sk3a1000kk9s","title":"SK3A1000KK9S - Hammond Power Solutions 1000 kVA 3-Phase Sentinel K Energy Efficient Transformer 600V 480D-480Y\/277V 60Hz Type 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSK3A1000KK9S\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eSK3A1000KK9S\u003c\/b\u003e is a 1000 kVA 3-phase energy efficient distribution transformer from Hammond Power Solutions Sentinel K series designed for general purpose low voltage applications.\u003cp\u003eThis transformer features a 600V delta primary and 480Y\/277V secondary voltage configuration, operating at 60 Hz frequency. It is a K-factor rated transformer compliant with DOE 2016 and NRCan 2019 energy efficiency standards, optimized for harmonic mitigating performance. The enclosure is a heavy duty ventilated Type 3R suitable for outdoor use with protection against rain and snow. It is constructed with aluminum windings and rated for a 150°C temperature rise.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 1000 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 600V Delta\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 480Y\/277V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eSeries: Sentinel K\u003c\/li\u003e\n\u003cli\u003eEnergy Efficiency: DOE 2016 \/ NRCan 2019 Compliant\u003c\/li\u003e\n\u003cli\u003eK-Factor Rated for Harmonic Mitigation\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: Type 3R Ventilated\u003c\/li\u003e\n\u003cli\u003eWinding Material: Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise: 150°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SK3A1000KK9S\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x3%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 2x3%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 1258.97\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=0, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 64 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 4% - 7.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH8-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 82in\/2083mm(H), 60in\/1524mm(W), 47in\/1194mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 1000\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=0\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPC : 803423129873\u003c\/li\u003e\n\u003cli\u003eWeight : 5990 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SK3A1000KK9S\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH8-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/ul\u003e","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62209102479519,"sku":"SK3A1000KK9S-New","price":84795.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SK3A1000KK9S.jpg?v=1757545242","url":"https:\/\/essentialparts.com\/products\/sk3a1000kk9s","provider":"Essential Electric Supply","version":"1.0","type":"link"}