{"product_id":"sg3c0150kd0c","title":"Hammond Power Solutions SG3C0150KD0C - 3-Phase Transformer 150 kVA 480D-240\/120V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3C0150KD0C\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3C0150KD0C is a three-phase general duty transformer designed for industrial power distribution applications. This 150 kVA unit features a 480V delta primary configuration with multiple 2.5% taps and delivers 240\/120V secondary output through mounting pad terminations. The transformer is housed in a Type 3R\/IP24 rated enclosure measuring 44.5\" H Ã— 31.5\" W Ã— 29.5\" D with ANSI 61 grey finish, operating with 150Â°C temperature rise and 220Â°C insulation class. It complies with DOE 2016, NRCAN 2019, and NMX 2021 efficiency regulations while meeting IBC 2018 seismic standards with Sds=2.0, z\/h=1, and lp=1.5 parameters. Typical applications include industrial facilities, manufacturing plants, and commercial buildings requiring reliable three-phase power conversion with 60Hz frequency operation and 50 dBA sound level performance.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: 480V primary, 240\/120V secondary\u003c\/li\u003e \u003cli\u003eCurrent: 150 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 44.5\" H Ã— 31.5\" W Ã— 29.5\" D\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5% standard\u003c\/li\u003e \u003cli\u003eSound Level: 50 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eVector Configuration: Dd0 (0Â°)\u003c\/li\u003e \u003cli\u003eCompliance: DOE 2016, NRCAN 2019, NMX 2021, IBC 2018 seismic\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3C0150KD0C\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 240\/120\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 150\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 44.5in\/1131mm(H), 31.5in\/801mm(W), 29.5in\/750mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 150\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dd0 (0Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423124670\u003c\/li\u003e\n\u003cli\u003eWeight : 1050 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3C0150KD0C\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208945553567,"sku":"SG3C0150KD0C-New","price":12069.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-sg3c0150kd0c-3-phase-transformer-150-kva-480d-240-120v-53687906304159.jpg?v=1766010923","url":"https:\/\/essentialparts.com\/products\/sg3c0150kd0c","provider":"Essential Electric Supply","version":"1.0","type":"link"}