{"product_id":"sg3c0045kd0c","title":"Hammond Power Solutions SG3C0045KD0C - 3-Phase Transformer 45kVA 480D-240\/120V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3C0045KD0C\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3C0045KD0C is a three-phase general duty transformer designed for industrial power distribution applications. This 45 kVA unit features a 480V delta primary configuration with multiple 2.5% taps and delivers 240\/120V secondary output, operating at 60Hz frequency with standard impedance ranging from 2.5% to 6.5%. The transformer is housed in a Type 3R\/IP24 rated enclosure measuring 28.75 inches high by 25.75 inches wide by 23.8 inches deep, finished in ANSI 61 grey with UL50 certification and mechanical lug secondary terminations. It complies with multiple efficiency standards including DOE 2016, NRCAN 2019, and NMX 2021, and meets seismic requirements for OSHPD and IBC 2018 with Sds=2.0, z\/h=1, and lp=1.5 parameters. Typical applications include industrial facilities, commercial buildings, and infrastructure projects requiring reliable three-phase power conversion with seismic resilience and low 45 dBA sound levels.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 480V Delta Primary, 240\/120V Secondary\u003c\/li\u003e \u003cli\u003eCurrent: 45 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5% Standard\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 28.75\" H Ã— 25.75\" W Ã— 23.8\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: OSHPD, IBC 2018\u003c\/li\u003e \u003cli\u003eEfficiency Standards: DOE 2016, NRCAN 2019, NMX 2021\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3C0045KD0C\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 240\/120\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 45\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH2-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 28.75in\/731mm(H), 25.75in\/655mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 45\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dd0 (0Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423124526\u003c\/li\u003e\n\u003cli\u003eWeight : 405 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3C0045KD0C\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH2-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208945324191,"sku":"SG3C0045KD0C-New","price":4807.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-sg3c0045kd0c-3-phase-transformer-45kva-480d-240-120v-53687906042015.jpg?v=1766010923","url":"https:\/\/essentialparts.com\/products\/sg3c0045kd0c","provider":"Essential Electric Supply","version":"1.0","type":"link"}