{"product_id":"q1c5xekf","title":"Q1C5XEKF - Hammond Power Solutions 1.5 kVA Single Phase Encapsulated Transformer 440-240-120\/240V 60Hz NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ1C5XEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ1C5XEKF\u003c\/b\u003e is a single phase encapsulated distribution transformer designed for hazardous locations and demanding environments. This Hammond Power Solutions model features a robust NEMA 3R enclosure and is built for reliable performance in industrial and commercial applications. This transformer is rated for 1.5 kVA and supports primary voltages of 440, 240, and 120\/240V with a 60 Hz frequency. It is constructed with copper windings and features a potted (encapsulated) design for protection against moisture and contaminants. The unit is wall-mountable and includes standard side and rear knock-outs for easy installation. It is UL Listed and CSA Certified, making it suitable for use in hazardous locations as defined by Class 1, Division 2 and Class I, Zone 2 standards. \u003cul\u003e \u003cli\u003ePart Number: Q1C5XEKF\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eType: Single Phase Encapsulated Transformer\u003c\/li\u003e \u003cli\u003eRating: 1.5 kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 440-240-120\/240V\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eMounting: Wall Mount\u003c\/li\u003e \u003cli\u003eWinding Material: Copper\u003c\/li\u003e \u003cli\u003eUL Listed\u003c\/li\u003e \u003cli\u003eCSA Certified\u003c\/li\u003e \u003cli\u003eHazardous Location Rated\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q1C5XEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 1.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 10.56in\/269mm(H), 5.88in\/150mm(W), 5.19in\/132mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 1.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423033224\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423033224\u003c\/li\u003e\n\u003cli\u003eWeight : 32 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q1C5XEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ3-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208936509599,"sku":"Q1C5XEKF-New","price":745.71,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q1C5XEKF.jpg?v=1757544194","url":"https:\/\/essentialparts.com\/products\/q1c5xekf","provider":"Essential Electric Supply","version":"1.0","type":"link"}