{"product_id":"q007yekf","title":"Q007YEKF - Hammond Power Solutions 7.5kVA Single Phase 208\/240\/277V Primary Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ007YEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ007YEKF\u003c\/b\u003e is a single-phase encapsulated transformer from Hammond Power Solutions HPS Titan Series designed for harsh and hazardous environments. This 7.5 kVA unit features multiple primary voltage inputs (208V, 240V, 277V) and delivers 120\/240V secondary output through copper windings. The transformer is potted for enhanced durability and environmental protection, making it suitable for Class 1 Division 2 and Class I Zone 2 hazardous locations. \u003cb\u003eKey Specifications\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003ePart Number: Q007YEKF\u003c\/li\u003e\n\u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eSeries: HPS Titan\u003c\/li\u003e\n\u003cli\u003eCapacity: 7.5 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 208\/240\/277V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eWinding Material: Copper\u003c\/li\u003e\n\u003cli\u003eDimensions: 10 inches W x 7.75 inches D x 17.25 inches H\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q007YEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277, 240, 208\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423033125\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423033125\u003c\/li\u003e\n\u003cli\u003eWeight : 115 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q007YEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208934772895,"sku":"Q007YEKF-New","price":2214.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q007YEKF.jpg?v=1757544152","url":"https:\/\/essentialparts.com\/products\/q007yekf","provider":"Essential Electric Supply","version":"1.0","type":"link"}