{"product_id":"q005xekf","title":"Q005XEKF - Hammond Power Solutions 5kVA Single Phase Encapsulated Transformer NEMA 3R 120\/240V 208\/415V 50\/60Hz","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ005XEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ005XEKF\u003c\/b\u003e is a single phase encapsulated transformer from Hammond Power Solutions, designed for reliable power distribution in demanding environments. This unit features dual primary and secondary voltage ratings, copper windings, and a robust NEMA 3R enclosure for protection against dust and moisture. The Q005XEKF transformer is part of the HPS Titan series, engineered for use in harsh and hazardous locations. It supports parallel and series connections for flexible wiring, and is suitable for both commercial and industrial applications. The encapsulated design ensures durability and long-term performance, while the compact size allows for easy installation in tight spaces. \u003cul\u003e \u003cli\u003e5 kVA capacity\u003c\/li\u003e \u003cli\u003eSingle phase\u003c\/li\u003e \u003cli\u003eDual primary voltage: 208\/415V\u003c\/li\u003e \u003cli\u003eDual secondary voltage: 120\/240V\u003c\/li\u003e \u003cli\u003e50\/60 Hz frequency\u003c\/li\u003e \u003cli\u003eCopper windings\u003c\/li\u003e \u003cli\u003eNEMA 3R enclosure\u003c\/li\u003e \u003cli\u003eWall mounting\u003c\/li\u003e \u003cli\u003eUL Listed\u003c\/li\u003e \u003cli\u003eCSA certified\u003c\/li\u003e \u003cli\u003eABS approved\u003c\/li\u003e \u003cli\u003eMeets ANSI 61 standards\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q005XEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423033064\u003c\/li\u003e\n\u003cli\u003eWeight : 105 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q005XEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205442719903,"sku":"Q005XEKF-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q005XEKF.jpg?v=1757544143","url":"https:\/\/essentialparts.com\/products\/q005xekf","provider":"Essential Electric Supply","version":"1.0","type":"link"}