{"product_id":"q002pekf","title":"Q002PEKF - Hammond Power Solutions 2kVA 1-Phase 600V to 120\/240V Encapsulated Transformer NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ002PEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ002PEKF\u003c\/b\u003e is a 2kVA single-phase encapsulated transformer from Hammond Power Solutions designed for industrial and harsh environments.\u003cp\u003eThis transformer features a primary voltage rating of 550\/575\/600V and a secondary voltage of 120\/240V. It belongs to the HPS Titan series, known for its rugged encapsulated design suitable for Class 1, Division 2 hazardous locations and marine duty applications. The unit is UL listed and CSA certified, with a Type 3R enclosure providing protection against weather and environmental conditions. It includes copper windings, an electrostatic shield, and standard wall mounting with keyhole slots for easy installation. The transformer operates at 60 Hz frequency and meets NEMA ST-20 sound level standards, ensuring quiet operation.\u003c\/p\u003e\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 2kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 550\/575\/600V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eMounting Type: Standard Wall Mount with Keyhole Slots\u003c\/li\u003e\n\u003cli\u003eSeries: HPS Titan\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Certified\u003c\/li\u003e\n\u003cli\u003eCopper Windings with Electrostatic Shield\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time.\u003c\/p\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q002PEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 600\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 2\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 2\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423032012\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423032012\u003c\/li\u003e\n\u003cli\u003eWeight : 40 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q002PEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208933953695,"sku":"Q002PEKF-New","price":622.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q002PEKF.jpg?v=1757544115","url":"https:\/\/essentialparts.com\/products\/q002pekf","provider":"Essential Electric Supply","version":"1.0","type":"link"}