{"product_id":"ph75mqmj","title":"PH75MQMJ - Hammond 75VA 1-Phase Encapsulated Control Transformer 240\/480V to 120\/240V Chassis Mount","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003ePH75MQMJ\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003ePH75MQMJ\u003c\/b\u003e is a 75VA encapsulated control transformer by Hammond designed for industrial applications requiring reliable voltage transformation.\u003cp\u003eThis transformer features a 1-phase encapsulated core construction with a primary voltage rating of 240\/480V (also compatible with 230\/460V and 220\/440V) and a secondary voltage of 120\/240V. It operates at 50\/60 Hz frequency and is chassis mountable, making it suitable for panel installations. The encapsulated design protects coils and terminations from moisture and dirt, enhancing durability in industrial environments. The PH75MQMJ is part of the HPS Imperator® series, known for handling high inrush currents typical of electromagnetic devices such as relays and motor starters.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower Rating: 75VA\u003c\/li\u003e\n\u003cli\u003ePhase: Single-phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 240\/480V (also supports 230\/460V, 220\/440V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Type: Chassis mount\u003c\/li\u003e\n\u003cli\u003eTransformer Type: Encapsulated core\u003c\/li\u003e\n\u003cli\u003eSeries: HPS Imperator®\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time.\u003c\/p\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: PH75MQMJ\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Industrial Control\u003c\/li\u003e\n\u003cli\u003eFamily : Imperator\u003c\/li\u003e\n\u003cli\u003eType : PH\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eKVA Rating : 0.075\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120x240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 55Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 0.140408\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 180Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Terminal Block\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423077945\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423077945\u003c\/li\u003e\n\u003cli\u003eWeight : 4 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/PH75MQMJ\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation_Product_Brochures\/HPS-Imperator-Encapsulated-Machine-Tool-Industrial-Control-Transformer-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond","offers":[{"title":"New","offer_id":42388012433567,"sku":"PH75MQMJ-New","price":80.97,"currency_code":"USD","in_stock":false},{"title":"Re-Certified","offer_id":42388012466335,"sku":"PH75MQMJ-ReCert","price":68.82,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/PH75MQMJ_1.jpg?v=1757539143","url":"https:\/\/essentialparts.com\/products\/ph75mqmj","provider":"Essential Electric Supply","version":"1.0","type":"link"}