{"product_id":"ph750memx","title":"Hammond Power Solutions PH750MEMX - Transformer 415\/400\/380V Primary (Seismic OSHPD)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003ePH750MEMX\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions PH750MEMX is a single-phase core and coil transformer designed for industrial power distribution applications. This transformer operates with primary voltages of 415V, 400V, or 380V at 50\/60Hz frequency and delivers secondary outputs of 110V or 220V through parallel or series connections. Constructed with copper windings and featuring an 80Â°C temperature rise with 130Â°C insulation class, the unit meets OSHPD compliance and IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5). The transformer utilizes standard terminal block primary terminations and is engineered for reliable performance in commercial and industrial facilities requiring robust power conversion with seismic certification.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase Core \u0026amp; Coil Transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 415V\/400V\/380V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 110x220V\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 80Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 130Â°C\u003c\/li\u003e \u003cli\u003eSeismic Compliance: OSHPD, IBC 2018\u003c\/li\u003e \u003cli\u003ePrimary Connection: Series (V)\u003c\/li\u003e \u003cli\u003eSecondary Connection: Parallel x Series (Vx2V)\u003c\/li\u003e \u003cli\u003eVector Configuration: 180Â°\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: PH750MEMX\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 415, 400, 380\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 110x220\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 80Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 1.11093\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 180Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Terminal Block, Terminal Block, Terminal Block\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423078492\u003c\/li\u003e\n\u003cli\u003eWeight : 21 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/PH750MEMX\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation_Product_Brochures\/HPS-Imperator-Encapsulated-Machine-Tool-Industrial-Control-Transformer-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208933134495,"sku":"PH750MEMX-New","price":367.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/PH750MEMX.jpg?v=1757544085","url":"https:\/\/essentialparts.com\/products\/ph750memx","provider":"Essential Electric Supply","version":"1.0","type":"link"}