{"product_id":"ph1000mgj","title":"Hammond Power Solutions PH1000MGJ - Transformer 1.48 EKVA Seismic Compliant","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003ePH1000MGJ\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions PH1000MGJ is a single-phase core and coil transformer designed for industrial power distribution applications. This transformer features versatile primary voltage compatibility with 380V, 277V, and 208V inputs and delivers secondary output of 120x240V through parallel x series connections. Constructed with copper windings and rated for 80Â°C temperature rise with 130Â°C insulation class, the unit operates at 50\/60Hz frequency and provides 1.48124 EKVA capacity. The transformer meets stringent seismic compliance standards including OSHPD and IBC 2018 with Sds=2.0, z\/h=1, and lp=1.5 parameters. It features standard terminal block primary terminations and 180Â° vector configuration, making it suitable for critical power applications requiring reliable performance in seismic zones.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase Core \u0026amp; Coil Transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 380, 277, 208V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120x240V\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eEKVA: 1.48124\u003c\/li\u003e \u003cli\u003eMaterial: Copper Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 80Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 130Â°C\u003c\/li\u003e \u003cli\u003eSeismic Compliance: OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e \u003cli\u003ePrimary Connection: Series (V)\u003c\/li\u003e \u003cli\u003eSecondary Connection: Parallel x Series (Vx2V)\u003c\/li\u003e \u003cli\u003eVector Configuration: 180Â°\u003c\/li\u003e \u003cli\u003ePrimary Termination: Terminal Block\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: PH1000MGJ\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 380, 277, 208\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120x240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 80Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 1.48124\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 180Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Terminal Block, Terminal Block, Terminal Block\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 080342307859\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423078591\u003c\/li\u003e\n\u003cli\u003eWeight : 26 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/PH1000MGJ\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation_Product_Brochures\/HPS-Imperator-Encapsulated-Machine-Tool-Industrial-Control-Transformer-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208927465631,"sku":"PH1000MGJ-New","price":428.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-ph1000mgj-transformer-1-48-ekva-seismic-compliant-53615147450527.jpg?v=1766010917","url":"https:\/\/essentialparts.com\/products\/ph1000mgj","provider":"Essential Electric Supply","version":"1.0","type":"link"}