{"product_id":"hda36100-square-d-100a-600v-3-pole-i-line-thermal-magnetic-circuit-breaker-powerpact-h","title":"HDA36100 - Square D 100A 600V 3 Pole I-Line Thermal Magnetic Circuit Breaker PowerPact H","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eHDA36100\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eHDA36100\u003c\/b\u003e is a Square D PowerPact H series 3 pole circuit breaker rated for 100 amps and 600 volts with thermal magnetic trip unit.This molded case circuit breaker features an interrupt rating of 25 kA at 240 VAC, 18 kA at 480 VAC, 14 kA at 600 VAC, and 20 kA at 250 VDC. It is designed for I-Line plug-in mounting and supports wire gauges from AWG 14 to 3\/0 aluminum or copper. The breaker is UL, CSA, CE, and IEC certified, suitable for power distribution applications requiring reliable overload and short circuit protection.\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003eAmperage: 100 A\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 600 V AC, 250 V DC\u003c\/li\u003e\n\u003cli\u003eNumber of Poles: 3P\u003c\/li\u003e\n\u003cli\u003eInterrupt Rating: 25 kA @ 240 V AC, 18 kA @ 480 V AC, 14 kA @ 600 V AC, 20 kA @ 250 V DC\u003c\/li\u003e\n\u003cli\u003eTrip Unit: Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003eMounting Type: I-Line plug-in\u003c\/li\u003e\n\u003cli\u003eWire Gauge: AWG 14 to 3\/0 aluminum\/copper\u003c\/li\u003e\n\u003cli\u003eSeries\/Frame: PowerPact H\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA, CE, IEC\u003c\/li\u003e\n\u003cli\u003eMagnetic Hold Current: 900 A\u003c\/li\u003e\n\u003cli\u003eMagnetic Trip Current: 1700 A\u003c\/li\u003e\n\u003cli\u003eDimensions: Height 9.73 in, Width 4.48 in, Depth 4.8 in\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: HDA36100\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Schneider Electric\u003c\/li\u003e\n\u003cli\u003eBrand : Square D\u003c\/li\u003e\n\u003cli\u003eCategory : Circuit Breaker\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Molded Case\u003c\/li\u003e\n\u003cli\u003eFamily : Powerpact\u003c\/li\u003e\n\u003cli\u003eType : HDA\u003c\/li\u003e\n\u003cli\u003eVoltage : 600\u003c\/li\u003e\n\u003cli\u003eAmperage : 100\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003ePoles : 3\u003c\/li\u003e\n\u003cli\u003eAIC rating : 18kA@480V\u003c\/li\u003e\n\u003cli\u003eConnection : I-Line Style Plug-In\u003c\/li\u003e\n\u003cli\u003eFunctions : LI - Long-Time and Instantaneous Trip\u003c\/li\u003e\n\u003cli\u003eTerminal Connection : I-Line, Lug\u003c\/li\u003e\n\u003cli\u003eFrame Size : H\u003c\/li\u003e\n\u003cli\u003eTemp Rating : -13â€“158 Â°F (-25â€“70 Â°C)\u003c\/li\u003e\n\u003cli\u003eMCM Size : Min. Wire Size 14 AWG (Cu\/Al) Max. Wire Size 3\/0 AWG (Cu\/Al)\u003c\/li\u003e\n\u003cli\u003eProtection : Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003ePhase Connection : ABC\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 785901419983\u003c\/li\u003e\n\u003cli\u003eGTIN : 00785901419983\u003c\/li\u003e\n\u003cli\u003eCountry of Origin : Mexico\u003c\/li\u003e\n\u003cli\u003eDimensions : 6.4 in (163 mm) x 4.09 in (104 mm) x 3.4 in (86 mm) (Height x Width x Depth)\u003c\/li\u003e\n\u003cli\u003eWeight : 5.549 \u003c\/li\u003e\n\u003cli\u003eStandards : UL, CSA, NEMA, NOM-003-SCFI-2000, IEC 60947-2\u003c\/li\u003e\n\u003cli\u003eCertification : UL, CSA, NOM\u003c\/li\u003e\n\u003cli\u003eWire Size : AWG 14...AWG 3\/0 aluminium\/copper terminal\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Square D","offers":[{"title":"New","offer_id":42254142308511,"sku":"HDA36100-New","price":545.85,"currency_code":"USD","in_stock":true},{"title":"Re-Certified","offer_id":42254142374047,"sku":"HDA36100-ReCert","price":421.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/products\/square-d-circuit-breakers-new-hda36100-square-d-100a-600v-3-pole-i-line-thermal-magnetic-circuit-breaker-powerpact-h-26600878997663.jpg?v=1766006802","url":"https:\/\/essentialparts.com\/products\/hda36100-square-d-100a-600v-3-pole-i-line-thermal-magnetic-circuit-breaker-powerpact-h","provider":"Essential Electric Supply","version":"1.0","type":"link"}