{"product_id":"fc2a0030pk","title":"Hammond Power Solutions FC2A0030PK - 3-Phase Transformer 30 kVA 600D\/480Y","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eFC2A0030PK\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions FC2A0030PK is a three-phase general duty transformer designed for industrial power distribution applications. It features a 600V delta primary and 480Y\/277V secondary configuration with 30 kVA capacity, constructed with aluminum windings rated for 135°C temperature rise and 220°C insulation class. The transformer is housed in a Type 4\/IP66 rated enclosure with ANSI 61 grey finish, measuring 21.88 inches high by 26.13 inches wide by 19.75 inches deep, and operates at 60Hz with sound levels below 50dBA. Compliant with UL50 standards and featuring Dyn1 vector configuration, this unit is suitable for commercial and industrial facilities requiring reliable power conversion with standard impedance range of 1-4%.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 600V Delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 480Y\/277V Wye-N\u003c\/li\u003e \u003cli\u003ekVA Rating: 30\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 4\/IP66\u003c\/li\u003e \u003cli\u003eSound Level: 50dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1-4%\u003c\/li\u003e \u003cli\u003eDimensions: 21.88\"H °— 26.13\"W °— 19.75\"D\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: FC2A0030PK\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 600D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 30\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSound Level : 50dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 4%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 4 \/ IP66\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DQT6-N4\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 21.88in\/556mm(H), 26.13in\/664mm(W), 19.75in\/502mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 30\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30°)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWeight : 495 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/FC2A0030PK\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-for-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DQT6-N4\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208914063519,"sku":"FC2A0030PK-New","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/FC2A0030PK.jpg?v=1757543330","url":"https:\/\/essentialparts.com\/products\/fc2a0030pk","provider":"Essential Electric Supply","version":"1.0","type":"link"}