{"product_id":"fc2a0009dk","title":"Hammond Power Solutions FC2A0009DK - 3-Phase Transformer 9kVA 240D-480Y\/277V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eFC2A0009DK\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions FC2A0009DK is a three-phase general duty transformer designed for industrial power distribution applications. This unit features a 240V delta primary connection with Â±5% FCAN\/FCBN taps and steps up to 480Y\/277V secondary with wye-N connection, delivering 9 kVA at 60Hz with aluminum windings rated for 135Â°C temperature rise and 220Â°C insulation class. The transformer is housed in a Type 4\/IP66 rated enclosure with ANSI 61 grey finish, measuring 16.38\" H Ã— 20.38\" W Ã— 12.88\" D (417mm Ã— 518mm Ã— 328mm), and operates at a low 45 dBA sound level with 2-6% standard impedance and YNd1 vector configuration. It complies with NEMA ST-20 sound standards and UL50 enclosure requirements, featuring a single electrostatic shield and standard nameplate. Typical applications include industrial machinery, manufacturing facilities, and commercial power systems requiring reliable voltage transformation.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Three-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 240V Delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 480Y\/277V Wye-N\u003c\/li\u003e \u003cli\u003ekVA Rating: 9 kVA\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eImpedance: 2% - 6%\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 4 \/ IP66\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eVector Configuration: YNd1 (-30Â°)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: FC2A0009DK\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 9\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2% - 6%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 4 \/ IP66\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DQT3A-N4\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 16.38in\/417mm(H), 20.38in\/518mm(W), 12.88in\/328mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 9\u003c\/li\u003e\n\u003cli\u003eVector Configuration : YNd1 (-30Â°)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWeight : 208 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/FC2A0009DK\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-for-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DQT3A-N4\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208913080479,"sku":"FC2A0009DK-New","price":2299.99,"currency_code":"USD","in_stock":true}],"url":"https:\/\/essentialparts.com\/products\/fc2a0009dk","provider":"Essential Electric Supply","version":"1.0","type":"link"}