{"product_id":"dm118kkc","title":"DM118KKC - Hammond Power Solutions 118kVA 480-480V 3-Phase Drive Isolation Transformer Copper Wound","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eDM118KKC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eDM118KKC\u003c\/b\u003e is a three-phase dry type drive isolation transformer designed for industrial applications requiring reliable power isolation and voltage transformation. This unit features a copper wound construction and is rated for 118kVA with a primary and secondary voltage of 480V. The DM118KKC is engineered to withstand overcurrent up to 150% of rated load for 60 seconds or 200% for 30 seconds, making it suitable for demanding drive environments. It is built with a robust insulation system and is designed for floor mounting. The transformer is constructed to meet UL and CSA short circuit withstand requirements, ensuring safety and reliability in critical installations. \u003cul\u003e \u003cli\u003ePart Number: DM118KKC\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eType: Three-Phase Dry Type Drive Isolation Transformer\u003c\/li\u003e \u003cli\u003eRating: 118kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 480V Delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 480Y\/277V\u003c\/li\u003e \u003cli\u003eConstruction: Copper Wound\u003c\/li\u003e \u003cli\u003eMounting: Floor Mount\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eImpedance: Typically 3 to 6%\u003c\/li\u003e \u003cli\u003eShort Circuit Withstand: Meets UL and CSA requirements\u003c\/li\u003e \u003cli\u003eInsulation System: 220°C (150°C rise)\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: DM118KKC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 1x5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 118\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification; approved for installation in US and LATAM\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=0, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 3% - 6%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NH3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 38in\/966mm(H), 26in\/661mm(W), 21in\/534mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 118\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=0\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423052553\u003c\/li\u003e\n\u003cli\u003eWeight : 785 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/DM118KKC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation_Product_Brochures\/HPS-Tribune-Non-Efficient-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NH3-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208906199199,"sku":"DM118KKC-New","price":9974.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/DM118KKC.jpg?v=1757543109","url":"https:\/\/essentialparts.com\/products\/dm118kkc","provider":"Essential Electric Supply","version":"1.0","type":"link"}