{"product_id":"c1fc50le","title":"C1FC50LE - Hammond 0.5kVA 1-Phase 240\/480V to 120\/240V Encapsulated Transformer NEMA 3R Wall Mount","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1FC50LE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1FC50LE\u003c\/b\u003e is a Hammond HPS Fortress encapsulated transformer designed for commercial and industrial applications requiring reliable single-phase power conversion. This unit features a robust NEMA 3R enclosure and is wall-mountable for flexible installation. The C1FC50LE transformer is built with an encapsulated core and copper windings, providing protection against moisture, contaminants, and corrosion. It is rated for 0.5kVA, with a primary voltage of 240\/480V and a secondary output of 120\/240V, operating at 60Hz. The transformer is suitable for general-purpose use and is recognized for its durability and safety in demanding environments. \u003cul\u003e \u003cli\u003eManufacturer: Hammond\u003c\/li\u003e \u003cli\u003eSeries: HPS Fortress\u003c\/li\u003e \u003cli\u003ePower Rating: 0.5kVA\u003c\/li\u003e \u003cli\u003ePhase: Single Phase\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 240\/480V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eCore Type: Encapsulated\u003c\/li\u003e \u003cli\u003eWinding Material: Copper\u003c\/li\u003e \u003cli\u003eAgency Approvals: UL Listed, CSA Certified\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1FC50LE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Fortress\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 500VA 240x480V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eKVA Rating : 0.5\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 95Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 0.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ1-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 7.19in\/183mm(H), 4.31in\/110mm(W), 5.56in\/142mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 0.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090692\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423090692\u003c\/li\u003e\n\u003cli\u003eWeight : 15 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1FC50LE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ1-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond","offers":[{"title":"New","offer_id":42676654145695,"sku":"C1FC50LE-New","price":157.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/file_name_21152_07c42387-04b7-468d-b7ee-95d809ead0e8.jpg?v=1757541027","url":"https:\/\/essentialparts.com\/products\/c1fc50le","provider":"Essential Electric Supply","version":"1.0","type":"link"}