{"product_id":"c1fc10le","title":"C1FC10LE - Hammond 100VA 1-Phase Dry Type Transformer 240\/480V Primary 120\/240V Secondary","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1FC10LE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1FC10LE\u003c\/b\u003e is a Hammond 100VA single-phase dry type transformer designed for reliable voltage conversion in industrial and commercial applications.\u003cp\u003eThis transformer features a primary voltage rating of 240\/480 volts and a secondary voltage rating of 120\/240 volts, operating at 60 Hz frequency. It is encapsulated for durability and protection, with copper windings and insulation rated for 130 degrees Celsius. The compact design measures approximately 3.69 inches wide, 5.06 inches deep, and 7.19 inches high, suitable for various mounting configurations. Certified to UL 50 and CSA standards, it meets ANSI 61 and NEMA ST-20 applicable standards, ensuring safety and performance compliance.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower Rating: 100 VA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 240\/480 V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eType: Dry Type, Encapsulated\u003c\/li\u003e\n\u003cli\u003eInsulation Temperature Rating: 130°C\u003c\/li\u003e\n\u003cli\u003eWinding Material: Copper\u003c\/li\u003e\n\u003cli\u003eDimensions: 3.69\" W x 5.06\" D x 7.19\" H\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, CSA, ANSI 61, NEMA ST-20\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time.\u003c\/p\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1FC10LE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Fortress\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 100VA 240x480V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eKVA Rating : 0.1\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 95Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 0.1\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ0-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 7.19in\/183mm(H), 3.69in\/94mm(W), 5.06in\/129mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 0.1\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423093594\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423093594\u003c\/li\u003e\n\u003cli\u003eWeight : 6 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1FC10LE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ0-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond","offers":[{"title":"New","offer_id":42676653162655,"sku":"C1FC10LE-New","price":117.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/file_name_21084_99c865c4-4a4a-472e-814b-40433f4bd940.jpg?v=1757541139","url":"https:\/\/essentialparts.com\/products\/c1fc10le","provider":"Essential Electric Supply","version":"1.0","type":"link"}