{"product_id":"c1fc05hr","title":"Hammond Power Solutions C1FC05HR - Transformer 50VA 480\/277V-277\/208V Copper","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1FC05HR\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1FC05HR is a single-phase general duty transformer designed for industrial power distribution applications. This 50VA transformer features primary voltage ratings of 480\/277V and secondary outputs of 277\/208V with series connections, constructed with copper windings and rated for 50\/60Hz operation. The unit is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 7.19 inches high by 3.69 inches wide by 5.06 inches deep, and operates with a 95Â°C temperature rise and 130Â°C insulation class. Compliant with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and NEMA ST-20 sound level requirements at 45dBA, this transformer meets rigorous industrial specifications. Typical applications include commercial lighting systems, control circuits, and industrial equipment requiring voltage transformation in harsh environments.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 480\/277V, Secondary 277\/208V\u003c\/li\u003e \u003cli\u003eCurrent: 50VA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 7.19\" H Ã— 3.69\" W Ã— 5.06\" D\u003c\/li\u003e \u003cli\u003eTemperature Rise: 95Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 130Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1FC05HR\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 50VA 480,277V-277,208V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 95Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 130Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 0.05\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads, Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ0-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 7.19in\/183mm(H), 3.69in\/94mm(W), 5.06in\/129mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 0.05\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 80342309375\u003c\/li\u003e\n\u003cli\u003eWeight : 6 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1FC05HR\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ0-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208865697951,"sku":"C1FC05HR-New","price":140.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1FC05HR.jpg?v=1757541122","url":"https:\/\/essentialparts.com\/products\/c1fc05hr","provider":"Essential Electric Supply","version":"1.0","type":"link"}