{"product_id":"c1f010ges","title":"C1F010GES - Hammond Power Solutions 10 kVA 208x416V to 120\/240V Single Phase Encapsulated Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F010GES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F010GES\u003c\/b\u003e is a 10 kVA single phase encapsulated transformer designed for power distribution applications.This transformer operates at 60 Hz frequency with primary voltages of 208 and 416 volts and secondary voltages of 120 and 240 volts. It features an epoxy and silica encapsulated construction to protect internal components from moisture and contaminants, ensuring prolonged operational life. The unit complies with IBC 2018 seismic standards and meets ANSI 61 and NEMA ST-20 sound level requirements. It is UL 50 and CSA approved, suitable for indoor and outdoor use with a Type 3R enclosure. The transformer includes factory-installed grounding lugs and standard wall mounting provisions.\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 10 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 208\/416 V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: Type 3R\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e\n\u003cli\u003eInsulation System: 180°C (115°C rise)\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, CSA, ANSI 61, NEMA ST-20\u003c\/li\u003e\n\u003cli\u003eSeismic Compliant: IBC 2018 Standards\u003c\/li\u003e\n\u003cli\u003eSound Level: 50 dBA\u003c\/li\u003e\n\u003cli\u003eConstruction: Epoxy and Silica Encapsulated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F010GES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 10kVA 208x416V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 208x416\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 10\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 20.88in\/531mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 10\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091552\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091552\u003c\/li\u003e\n\u003cli\u003eWeight : 185 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F010GES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864583839,"sku":"C1F010GES-New","price":1625.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-c1f010ges-hammond-power-solutions-10-kva-208x416v-to-120-240v-single-phase-encapsulated-transformer-53687839948959.jpg?v=1766010899","url":"https:\/\/essentialparts.com\/products\/c1f010ges","provider":"Essential Electric Supply","version":"1.0","type":"link"}