{"product_id":"c1f007hrs","title":"Hammond Power Solutions C1F007HRS - Transformer 7.5kVA 480\/277V-277\/208V Aluminum","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007HRS\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F007HRS is a general duty transformer designed for industrial power distribution applications. This single-phase unit features primary voltages of 480\/277V and secondary voltages of 277\/208V with a 7.5 kVA capacity operating at 50\/60 Hz frequency. The transformer is constructed with aluminum windings and housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 20.88 inches high by 12.25 inches wide by 9.25 inches deep. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features a 135Â°C temperature rise with 180Â°C insulation class. Typical applications include commercial and industrial power systems requiring reliable voltage transformation with 45 dBA sound level operation and 1-5% impedance characteristics.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 480\/277V, Secondary 277\/208V\u003c\/li\u003e \u003cli\u003eCurrent: 7.5 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 20.88\" H Ã— 12.25\" W Ã— 9.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 1-5% standard\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007HRS\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 480,277V-277,208V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 20.88in\/531mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092610\u003c\/li\u003e\n\u003cli\u003eWeight : 170 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007HRS\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864288927,"sku":"C1F007HRS-New","price":1586.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-c1f007hrs-transformer-7-5kva-480-277v-277-208v-aluminum-53687839588511.jpg?v=1766010899","url":"https:\/\/essentialparts.com\/products\/c1f007hrs","provider":"Essential Electric Supply","version":"1.0","type":"link"}