{"product_id":"bgl26125-schneider-electric-powerpact-b-circuit-breaker-125-amp-2-pole-600y-347vac-18ka-interrupt","title":"BGL26125 - Schneider Electric PowerPact B Circuit Breaker 125 Amp 2 Pole 600Y\/347VAC 18kA Interrupt","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eBGL26125\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eBGL26125\u003c\/b\u003e is a Schneider Electric PowerPact B series molded case circuit breaker designed for reliable industrial power protection.This 2 pole circuit breaker is rated for 125 amps with a maximum operational voltage of 600Y\/347 VAC. It features a thermal-magnetic trip unit and an interrupt rating of 18kA at 600Y\/347 VAC, meeting UL 489 standards. The breaker has an 80% continuous current rating and is designed for DIN rail mounting, providing compact and efficient installation. It carries a G interrupt rating with additional interrupt capacities of 65kA at 240 VAC and 35kA at 480 VAC. The breaker is UL listed and built for durability and safety in demanding electrical environments.\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003eAmperage: 125 Amp\u003c\/li\u003e\n\u003cli\u003ePoles: 2\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 600Y\/347 VAC\u003c\/li\u003e\n\u003cli\u003eInterrupt Rating: 18kA at 600Y\/347 VAC\u003c\/li\u003e\n\u003cli\u003eAdditional Interrupt Ratings: 65kA at 240 VAC, 35kA at 480 VAC\u003c\/li\u003e\n\u003cli\u003eFrame Type: PowerPact B\u003c\/li\u003e\n\u003cli\u003eTrip Unit: Thermal-Magnetic\u003c\/li\u003e\n\u003cli\u003eContinuous Current Rating: 80%\u003c\/li\u003e\n\u003cli\u003eMounting Type: DIN Rail\u003c\/li\u003e\n\u003cli\u003eUL Listed: UL 489\u003c\/li\u003e\n\u003cli\u003eInterrupt Code: G\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: BGL26125\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Schneider Electric\u003c\/li\u003e\n\u003cli\u003eBrand : Schneider Electric\u003c\/li\u003e\n\u003cli\u003eCategory : Circuit Breaker\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Molded Case\u003c\/li\u003e\n\u003cli\u003eFamily : Powerpact\u003c\/li\u003e\n\u003cli\u003eType : BGL\u003c\/li\u003e\n\u003cli\u003eVoltage : 600\u003c\/li\u003e\n\u003cli\u003eAmperage : 125\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003ePoles : 2\u003c\/li\u003e\n\u003cli\u003eAIC rating : 35kA@480V\u003c\/li\u003e\n\u003cli\u003eConnection : Feed-Thru\u003c\/li\u003e\n\u003cli\u003eFunctions : LI - Long-Time and Instantaneous\u003c\/li\u003e\n\u003cli\u003eTerminal Connection : Everlink Lug Both Ends\u003c\/li\u003e\n\u003cli\u003eFrame Size : 125A\/BG\u003c\/li\u003e\n\u003cli\u003eTemp Rating : -13â€“158 Â°F (-25â€“70 Â°C)\u003c\/li\u003e\n\u003cli\u003eMCM Size : Min. Wire Size 14 AWG, 6 AWG Max. Wire Size 2 AWG, 3 AWG\u003c\/li\u003e\n\u003cli\u003eBreaker Type : Standard\u003c\/li\u003e\n\u003cli\u003eProtection : Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003ePhase Connection : Not Applicable\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPC : 785901074656\u003c\/li\u003e\n\u003cli\u003eGTIN : 00785901074656\u003c\/li\u003e\n\u003cli\u003eCountry of Origin : United States\u003c\/li\u003e\n\u003cli\u003eDimensions : 5.4 in (137 mm) x 2.1 in (54 mm) x 3.1 in (80 mm) (Height x Width x Depth)\u003c\/li\u003e\n\u003cli\u003eWeight : 2.006 \u003c\/li\u003e\n\u003cli\u003ePanel Type : Electrical Distribution Equipment, Industrial Control Panels\u003c\/li\u003e\n\u003cli\u003eStandards : NMX J-266, EN\/IEC 60947-2, UL 489, CSA C22.2 No 5, GB 14048.2, NEMA AB1, EN\/IEC 60947-5-1\u003c\/li\u003e\n\u003cli\u003eCertification : UL, IEC, CCC, EAC, CSA, NOM\u003c\/li\u003e\n\u003cli\u003eWire Size : AWG 6...AWG 2\/0 fine stranded aluminium\/copper\u003cbr\u003e AWG 14...AWG 3\/0 rigid or stranded aluminium\/copper\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          \u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"New","offer_id":45020989128863,"sku":"BGL26125-New","price":1551.46,"currency_code":"USD","in_stock":true},{"title":"Re-Certified","offer_id":45031234961567,"sku":"BGL26125-ReCert","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/BGL26125_1.svg?v=1717532710","url":"https:\/\/essentialparts.com\/products\/bgl26125-schneider-electric-powerpact-b-circuit-breaker-125-amp-2-pole-600y-347vac-18ka-interrupt","provider":"Essential Electric Supply","version":"1.0","type":"link"}