{"product_id":"bda24060y1-square-d-60a-480y-277vac-2-pole-thermal-magnetic-circuit-breaker-b-frame-i-line","title":"BDA24060Y1 - Square D 60A 480Y\/277VAC 2-Pole Thermal Magnetic Circuit Breaker B-Frame I-Line","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eBDA24060Y1\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eBDA24060Y1\u003c\/b\u003e is a Square D 2-pole thermal magnetic molded case circuit breaker rated for 60 amps and 480Y\/277VAC voltage. This circuit breaker features a B-Frame PowerPact BDA series design with an 18kA interrupting rating at 480 volts. It uses an I-Line style plug-in connection and provides long time and instantaneous trip protection. The breaker supports line and load lug terminal connections and accommodates wire sizes from AWG 14 to 2\/0 aluminum or copper. It is UL, CSA, CE, NEMA, IEC, and RoHS certified, suitable for industrial and commercial power distribution applications. \u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003eAmperage: 60 Amps\u003c\/li\u003e\n\u003cli\u003eVoltage Rating: 480Y\/277VAC\u003c\/li\u003e\n\u003cli\u003ePoles: 2\u003c\/li\u003e\n\u003cli\u003eFrame Type: B-Frame (BDA Series)\u003c\/li\u003e\n\u003cli\u003eInterrupting Rating: 18kA at 480V\u003c\/li\u003e\n\u003cli\u003eTrip Unit: Thermal Magnetic with Long Time and Instantaneous Trip\u003c\/li\u003e\n\u003cli\u003eConnection Type: I-Line Style Plug-In\u003c\/li\u003e\n\u003cli\u003eTerminal Connection: Line and Load Lug\u003c\/li\u003e\n\u003cli\u003eWire Gauge: AWG 14 to 2\/0 Aluminum\/Copper\u003c\/li\u003e\n\u003cli\u003eCertifications: UL, CSA, CE, NEMA, IEC, RoHS\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: -13 to 158°F\u003c\/li\u003e\n\u003cli\u003eColor: Gray\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: BDA24060Y1\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Schneider Electric\u003c\/li\u003e\n\u003cli\u003eBrand : Square D\u003c\/li\u003e\n\u003cli\u003eCategory : Circuit Breaker\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Molded Case\u003c\/li\u003e\n\u003cli\u003eFamily : PowerPact B\u003c\/li\u003e\n\u003cli\u003eType : BDA\u003c\/li\u003e\n\u003cli\u003eVoltage : 480\u003c\/li\u003e\n\u003cli\u003eAmperage : 60\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003ePoles : 2\u003c\/li\u003e\n\u003cli\u003eAIC rating : 18@480VAC\u003c\/li\u003e\n\u003cli\u003eConnection : I-Line\u003c\/li\u003e\n\u003cli\u003eFunctions : Long Time and Instantaneous Trip\u003c\/li\u003e\n\u003cli\u003eTerminal Connection : Al Mechanical Lug OFF End, I-Line ON End\u003c\/li\u003e\n\u003cli\u003eFrame Size : 125A\/BD\u003c\/li\u003e\n\u003cli\u003eTemp Rating : -13â€“158 Â°F (-25â€“70 Â°C)\u003c\/li\u003e\n\u003cli\u003eMCM Size : Min. Wire Size 14 AWG Max. Wire Size 2 AWG\u003c\/li\u003e\n\u003cli\u003eBreaker Type : Standard\u003c\/li\u003e\n\u003cli\u003eProtection : Thermal Magnetic\u003c\/li\u003e\n\u003cli\u003ePhase Connection : AB\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 785901017097\u003c\/li\u003e\n\u003cli\u003eGTIN : 03606481151889\u003c\/li\u003e\n\u003cli\u003eCountry of Origin : Mexico\u003c\/li\u003e\n\u003cli\u003eDimensions : 5.4 in (137 mm) x 2.1 in (54 mm) x 3.5 in (89 mm) (Height x Width x Depth)\u003c\/li\u003e\n\u003cli\u003eWeight : 3.13 lb\u003c\/li\u003e\n\u003cli\u003ePanel Type : Electrical Distribution Equipment, Industrial Control Panels\u003c\/li\u003e\n\u003cli\u003eStandards : CSA C22.2 No 5, UL 489, GB 14048.2, EN\/IEC 60947-2, EN\/IEC 60947-5-1, NEMA AB1, NMX J-266\u003c\/li\u003e\n\u003cli\u003eCertification : UL, IEC, CCC, EAC, CSA, NOM\u003c\/li\u003e\n\u003cli\u003eWire Size : AWG 14...AWG 2\/0 aluminium\/copper\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Square D","offers":[{"title":"New","offer_id":44934237847711,"sku":"BDA24060Y1-New","price":505.31,"currency_code":"USD","in_stock":true},{"title":"Re-Certified","offer_id":45136917463199,"sku":"BDA24060Y1-ReCert","price":305.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/BDA24060Y1.jpg?v=1708557031","url":"https:\/\/essentialparts.com\/products\/bda24060y1-square-d-60a-480y-277vac-2-pole-thermal-magnetic-circuit-breaker-b-frame-i-line","provider":"Essential Electric Supply","version":"1.0","type":"link"}