{"title":"Hammond Freight","description":"","products":[{"product_id":"sg3a0045kb","title":"Hammond Power Solutions SG3A0045KB - Dry Type Transformer 45 kVA 480D-208Y\/120V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3A0045KB\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3A0045KB is a dry-type distribution transformer designed for industrial power conversion applications. This three-phase Sentinel G transformer provides voltage transformation from 480V delta primary to 208Y\/120V secondary with a 45 kVA capacity and operates at 60Hz with aluminum windings rated for 150å¡C temperature rise. The unit features a Type 3R\/IP24 enclosure with ANSI 61 grey finish measuring 28.75\" H ÌÑ 25.75\" W ÌÑ 23.8\" D and produces only 45 dBA sound levels. It complies with DOE 2016, NRCan 2019, and NMX 2021 efficiency standards while meeting OSHPD and IBC 2018 seismic requirements for Sds=2.0 applications. Typical applications include commercial buildings, industrial facilities, and infrastructure projects requiring reliable power distribution with seismic resilience.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Dry Type Distribution Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 480V Delta Primary \/ 208Y\/120V Secondary\u003c\/li\u003e \u003cli\u003eCurrent: 45 kVA Capacity\u003c\/li\u003e \u003cli\u003ePhase: 3-Phase\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150å¡C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220å¡C\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5%\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eDimensions: 28.75\" H ÌÑ 25.75\" W ÌÑ 23.8\" D\u003c\/li\u003e \u003cli\u003eStandards: DOE 2016, NRCan 2019, NMX 2021, IBC 2018 Seismic\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3A0045KB\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Distribution Equipment\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Transformers\u003c\/li\u003e\n\u003cli\u003eSection  : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Sentinel G\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 208Y\/120\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 45\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH2-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 28.75in\/731mm(H), 25.75in\/655mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 45\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423123536\u003c\/li\u003e\n\u003cli\u003eDimensions : 23.8 in L x 25.8 in W x 28.8 in H 28.8 in H x 25.8 in W x 23.8 in D\u003c\/li\u003e\n\u003cli\u003eWeight : 355 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":54348040732831,"sku":"SG3A0045KB-New","price":2974.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3A0045KB_1.jpg?v=1757539184"},{"product_id":"pfk3","title":"PFK3","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003ePFK3\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions PFK3 Transformer is a dry-type control transformer designed for industrial power distribution applications. It operates at 600V maximum voltage with a 3 kVA power rating, providing reliable voltage transformation for control circuits. The transformer features a compact, open-style construction with durable insulation systems suitable for demanding environments. This unit is engineered to meet relevant industry standards for safety and performance in electrical systems. It is commonly used in machine tools, industrial control panels, and automation equipment where consistent low-voltage power is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Dry-Type Control Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 600V Maximum\u003c\/li\u003e \u003cli\u003eCurrent: 3 kVA Rating\u003c\/li\u003e \u003cli\u003eEnclosure Grade: N\/A (Open Style)\u003c\/li\u003e \u003cli\u003eItem Category: 5\u003c\/li\u003e \u003c\/ul\u003e      Hammond Power Solutions PFK3 - Control Transformer 3 kVA 600V Industrial Grade \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: PFK3\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423077754\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423077754\u003c\/li\u003e\n\u003cli\u003eWeight : 1600 \u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/PFK3\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62187967905951,"sku":"PFK3-New","price":10.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/PFK3_1.jpg?v=1755891006"},{"product_id":"pfk6","title":"Hammond Power Solutions PFK6 - Dry-Type Transformer 6kVA 600V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003ePFK6\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions PFK6 Transformer is a dry-type control transformer designed for industrial power distribution applications. It operates at 600V maximum voltage with a 6kVA power rating, featuring a compact and robust construction suitable for demanding environments. The transformer complies with relevant industry standards for electrical safety and performance. It is commonly used in machine tools, control panels, and industrial automation systems.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Dry-Type Control Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 600V Maximum\u003c\/li\u003e \u003cli\u003eCurrent: 6kVA Power Rating\u003c\/li\u003e \u003cli\u003eEnclosure Grade: N\/A\u003c\/li\u003e \u003cli\u003eItem Category: 5\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: PFK6\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423077785\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423077785\u003c\/li\u003e\n\u003cli\u003eWeight : 1600 \u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/PFK6\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62188019253407,"sku":"PFK6-New","price":12.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/PFK6_1.jpg?v=1755891015"},{"product_id":"c1f002jes","title":"Hammond Power Solutions C1F002JES - Transformer 2kVA 380\/347V-120\/240V Copper","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F002JES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F002JES is a general duty single-phase transformer designed for industrial power distribution applications. This 2 kVA transformer features primary voltages of 380\/347V and secondary voltages of 120\/240V with copper windings and operates at 50\/60Hz frequency. The unit is housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 11.75 inches high by 7.06 inches wide by 6.25 inches deep, and produces a maximum sound level of 45 dBA. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features Class 180Â°C insulation with 135Â°C temperature rise. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 380\/347V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 2 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" H Ã— 7.06\" W Ã— 6.25\" D\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F002JES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 2kVA 380,347V-120\/240V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 380, 347\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 2\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 2\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090784\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423090784\u003c\/li\u003e\n\u003cli\u003eWeight : 52 lb\u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F002JES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62188284313759,"sku":"C1F002JES-New","price":611.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F002JES.jpg?v=1757541037"},{"product_id":"sg3n0100le","title":"SG3N0100LE - Hammond Power Solutions 100kVA 240x480V\/120-240V Single Phase Dry Type Transformer NEMA 3R Aluminum Wound","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3N0100LE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eSG3N0100LE\u003c\/b\u003e is a single-phase, 100kVA dry type transformer designed for general purpose distribution applications with a dual primary and secondary voltage configuration. This transformer is built for reliable performance in a variety of industrial and commercial environments. The SG3N0100LE features a robust NEMA 3R enclosure, aluminum windings, and is rated for 600V or below. It is suitable for supplying appliance, lighting, heating, motorized machine, and power loads from electrical distribution systems. The transformer is energy efficient and compliant with DOE2016 and NRCan 2019 standards. \u003cul\u003e \u003cli\u003ePart Number: SG3N0100LE\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003ePhase: Single Phase\u003c\/li\u003e \u003cli\u003ePower Rating: 100kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 240x480V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eEnclosure Type: NEMA 3R\u003c\/li\u003e \u003cli\u003eWinding Material: Aluminum\u003c\/li\u003e \u003cli\u003eMounting Type: Floor (optional wall\/ceiling)\u003c\/li\u003e \u003cli\u003eInsulation System: 220°C (150°C rise)\u003c\/li\u003e \u003cli\u003eApprovals: UL, CSA\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3N0100LE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eKVA Rating : 100 kVA\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 100\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=0, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 3% - 6.1%\u003c\/li\u003e\n\u003cli\u003eTermination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 36in\/915mm(H), 28.25in\/718mm(W), 27in\/686mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 100\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=0\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423140687\u003c\/li\u003e\n\u003cli\u003eWeight : 535 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3N0100LE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH3-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62204219981983,"sku":"SG3N0100LE-New","price":6882.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3N0100LE.jpg?v=1757544693"},{"product_id":"mg3a0015rkschc0","title":"Hammond Power Solutions MG3A0015RKSCHC0 - 15 kVA Transformer 2400D-480Y\/277V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eMG3A0015RKSCHC0\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions MG3A0015RKSCHC0 is a three-phase general duty transformer designed for industrial power distribution applications. This unit features a 2400V delta primary connection stepping down to 480Y\/277V secondary with a 15 kVA capacity and operates at 60Hz frequency with 130Â°C temperature rise and 200Â°C insulation class. The transformer is housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 731mm(H) x 655mm(W) x 605mm(D), and produces a maximum sound level of 45 dBA. It complies with DOE 2016, NRCAN 2019, and NMX 2021 efficiency regulations while meeting seismic standards including OSHPD and IBC 2018 with Sds=2.0, z\/h=1, and lp=1.5 parameters. This transformer is suitable for commercial and industrial facilities requiring reliable power conversion with seismic resilience.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-phase general duty transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 2400V delta\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 480Y\/277V wye-n\u003c\/li\u003e \u003cli\u003eStandard kVA: 15\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eTemperature Rise: 130Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 200Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5%\u003c\/li\u003e \u003cli\u003eEnclosure Type: Type 3R \/ IP24\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eVector Configuration: Dyn1 (-30Â°)\u003c\/li\u003e \u003cli\u003eEfficiency Compliance: DOE 2016, NRCAN 2019, NMX 2021\u003c\/li\u003e \u003cli\u003eSeismic Compliance: OSHPD, IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: MG3A0015RKSCHC0\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 2400D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 130Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 200Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 16.4034\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (IEEE C57.12.01)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 28.75in\/731mm(H), 25.75in\/655mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 15\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : 1x5%\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Mounting Pads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWeight : 170 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/MG3A0015RKSCHC0\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Medium_Voltage_Distribution_Transformers\/HPS-Millennium-G-VPI-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH2-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205054451871,"sku":"MG3A0015RKSCHC0-New","price":11430.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/MG3A0015RKSCHC0.jpg?v=1757543559"},{"product_id":"crx0180ac","title":"Hammond Power Solutions CRX0180AC - 3-Phase Reactor 180A (Core \u0026 Coil)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0180AC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions CRX0180AC is a three-phase core and coil transformer designed for industrial power conditioning applications. It operates at 60 Hz with a rated current of 180A and features a no-load power loss of 180W. The reactor is constructed with a compact footprint, measuring 7 inches (178mm) in height, 9.25 inches (235mm) in width, and 8.88 inches (226mm) in depth. This unit is engineered to meet industry standards for reliable performance in demanding environments. It is typically utilized in variable frequency drive (VFD) systems and other industrial automation equipment to mitigate harmonic distortion and protect sensitive components.     \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Three-Phase Core \u0026amp; Coil Transformer\u003c\/li\u003e \u003cli\u003eRated Current: 180A\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eNo-Load Power Loss (NPL): 180W\u003c\/li\u003e \u003cli\u003eDimensions: 7in\/178mm (H) x 9.25in\/235mm (W) x 8.88in\/226mm (D)\u003c\/li\u003e \u003cli\u003eItem Category: 5\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0180AC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 180A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 180W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 7in\/178mm(H), 9.25in\/235mm(W), 8.88in\/226mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423118266\u003c\/li\u003e\n\u003cli\u003eWeight : 54 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0180AC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205212295327,"sku":"CRX0180AC-New","price":622.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0180AC.jpg?v=1757542129"},{"product_id":"crx0180bc","title":"Hammond Power Solutions CRX0180BC - Three-Phase Reactor 180A (Core \u0026 Coil)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0180BC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions CRX0180BC is a three-phase reactor designed for power conditioning and harmonic mitigation in industrial electrical systems. This core and coil reactor operates at 60Hz frequency with a rated current of 180A and features a no-load power loss of 250W. The unit is constructed with a compact footprint, measuring 10.8 inches in width, 10 inches in height, and 8.38 inches in depth (275mm x 254mm x 213mm). It meets industry standards for Category 5 applications, ensuring reliable performance in demanding environments. Typical applications include variable frequency drive systems, UPS systems, and other scenarios requiring current limiting and power quality improvement.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Three-Phase Reactor, Core \u0026amp; Coil\u003c\/li\u003e \u003cli\u003eRated Current: 180A\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eWatts Loss (NPL): 250W\u003c\/li\u003e \u003cli\u003eApplication Category: 5\u003c\/li\u003e \u003cli\u003eDimensions: 10.8in (W) x 10in (H) x 8.38in (D) \/ 275mm x 254mm x 213mm\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0180BC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 180A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 250W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 10in\/254mm(H), 10.8in\/275mm(W), 8.38in\/213mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423118273\u003c\/li\u003e\n\u003cli\u003eWeight : 63 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0180BC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205212983455,"sku":"CRX0180BC-New","price":915.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0180BC.jpg?v=1757542132"},{"product_id":"crx0240be","title":"Hammond Power Solutions CRX0240BE - Transformer 240A 435W Loss","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0240BE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions CRX0240BE is a three-phase transformer designed for industrial power distribution applications. It operates at 60Hz with a rated current of 240A and features a nominal power loss of 435W. The unit is housed in a standard-grade enclosure with ANSI 61 Grey, UL50 finish and measures 25.9 inches (658mm) in height, 26.1 inches (663mm) in width, and 20.5 inches (521mm) in depth, constructed without an IR window. This transformer meets industry standards for reliable performance in demanding environments. It is suitable for various industrial applications requiring robust three-phase power conversion and distribution.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-Phase Transformer\u003c\/li\u003e \u003cli\u003eVoltage: N\/A\u003c\/li\u003e \u003cli\u003eCurrent: 240A\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eEnclosure Grade: Standard\u003c\/li\u003e \u003cli\u003eEnclosure Finish: ANSI 61 Grey, UL50\u003c\/li\u003e \u003cli\u003eEnclosure Dimensions: 25.9in\/658mm(H) x 26.1in\/663mm(W) x 20.5in\/521mm(D)\u003c\/li\u003e \u003cli\u003eWatts Loss (NPL): 435W\u003c\/li\u003e \u003cli\u003eEnclosure IR Window: No\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0240BE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : CH4-N1\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 25.9in\/658mm(H), 26.1in\/663mm(W), 20.5in\/521mm(D)\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003eRated Current : 240A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 435W\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423119379\u003c\/li\u003e\n\u003cli\u003eWeight : 195 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0240BE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/CH4-N1\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205214851231,"sku":"CRX0240BE-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0240BE.jpg?v=1757542205"},{"product_id":"crx0242bc","title":"Hammond Power Solutions CRX0242BC - Three-Phase Reactor 242A (360W NPL)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0242BC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions CRX0242BC is a three-phase reactor designed for power conditioning and harmonic mitigation in industrial electrical systems. This core and coil reactor operates at 60Hz frequency with a rated current of 242A and features a no-load power loss of 360W. The unit features compact reactor dimensions of 10 inches (254mm) in height, 11.05 inches (281mm) in width, and 9.5 inches (242mm) in depth, providing a robust construction suitable for demanding environments. It complies with industry standards for industrial power quality applications, falling under item category 5 for electrical components. Typical applications include variable frequency drive systems, UPS systems, and other installations requiring current limiting and harmonic filtering to protect sensitive equipment and improve power factor.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-Phase Reactor\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eRated Current: 242A\u003c\/li\u003e \u003cli\u003eWatts Loss (NPL): 360W\u003c\/li\u003e \u003cli\u003eEnclosure Type: Core \u0026amp; Coil\u003c\/li\u003e \u003cli\u003eDimensions: 10in\/254mm(H) x 11.05in\/281mm(W) x 9.5in\/242mm(D)\u003c\/li\u003e \u003cli\u003eItem Category: 5\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0242BC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 242A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 360W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 10in\/254mm(H), 11.05in\/281mm(W), 9.5in\/242mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423118464\u003c\/li\u003e\n\u003cli\u003eWeight : 87 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0242BC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205214883999,"sku":"CRX0242BC-New","price":1135.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0242BC.jpg?v=1757542211"},{"product_id":"crx0302bc","title":"Hammond Power Solutions CRX0302BC - 3-Phase Transformer 302A 475W NPL","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0302BC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions CRX0302BC is a three-phase core and coil transformer designed for industrial power conditioning applications. It operates at 60Hz with a rated current of 302A and features a no-load power loss of 475W. The reactor is constructed with a compact footprint measuring 14.5 inches (369mm) in height, 13.75 inches (350mm) in width, and 11.38 inches (290mm) in depth. This unit is engineered to meet rigorous industrial standards for reliable performance. It is typically utilized in demanding environments such as manufacturing facilities and power distribution systems.     \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Three-Phase Core \u0026amp; Coil Transformer\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eRated Current: 302A\u003c\/li\u003e \u003cli\u003eWatts Loss (NPL): 475W\u003c\/li\u003e \u003cli\u003eDimensions: 14.5in\/369mm (H) x 13.75in\/350mm (W) x 11.38in\/290mm (D)\u003c\/li\u003e \u003cli\u003eItem Category: 5\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0302BC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 302A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 475W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 14.5in\/369mm(H), 13.75in\/350mm(W), 11.38in\/290mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423118624\u003c\/li\u003e\n\u003cli\u003eWeight : 171 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0302BC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205216587935,"sku":"CRX0302BC-New","price":1346.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0302BC.jpg?v=1757542278"},{"product_id":"crx0361bc","title":"CRX0361BC - Hammond Power Solutions 361A 0.10mH 60Hz Line Reactor","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0361BC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eCRX0361BC\u003c\/b\u003e is a three-phase line reactor from Hammond Power Solutions designed for motor and drive protection in industrial and commercial applications. This Centurion R series reactor features a core and coil enclosure with natural convection cooling and delivers reliable performance across standard voltage ratings. \u003cb\u003eCRX0361BC\u003c\/b\u003e specifications include 361 amperes rated current, 0.10 millihenry inductance, 60 hertz frequency, and copper construction. The reactor is available in multiple impedance ratings and voltage options to meet diverse system requirements. \u003cb\u003eKey Specifications\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRated Current: 361 Amperes\u003c\/li\u003e\n\u003cli\u003eInductance: 0.10 millihenry\u003c\/li\u003e\n\u003cli\u003eSystem Frequency: 60 Hertz\u003c\/li\u003e\n\u003cli\u003eSystem Voltage Ratings: 208V, 240V, 480V, 575V, 600V\u003c\/li\u003e\n\u003cli\u003eImpedance Ratings: 1.5%, 3%, and 5%\u003c\/li\u003e\n\u003cli\u003ePhase Configuration: Three Phase\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: Core and Coil\u003c\/li\u003e\n\u003cli\u003eCooling Method: Natural Convection\u003c\/li\u003e\n\u003cli\u003eDielectric Strength: 4000 volts for 1 minute\u003c\/li\u003e\n\u003cli\u003eFrame Size: 4U\u003c\/li\u003e\n\u003cli\u003ePower Loss: 445 watts\u003c\/li\u003e\n\u003cli\u003eWarranty: 10 year limited warranty\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0361BC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 361A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 445W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 12.5in\/318mm(H), 13.75in\/350mm(W), 11.38in\/290mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423118709\u003c\/li\u003e\n\u003cli\u003eWeight : 147 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0361BC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205217996959,"sku":"CRX0361BC-New","price":1655.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0361BC.jpg?v=1757542305"},{"product_id":"crx0720ac","title":"CRX0720AC - Hammond Power Solutions 720A 480V 3-Phase Line Reactor Centurion R Series","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eCRX0720AC\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eCRX0720AC\u003c\/b\u003e is a Hammond Power Solutions 720 Amp, 480 Volt, 3-Phase Line Reactor from the Centurion R Series designed for industrial power applications.\u003cb\u003eCRX0720AC\u003c\/b\u003e features a core and coil construction with a 3% impedance rating, rated for 600 HP at 60 Hz frequency. It is UL listed and CSA certified, suitable for use in systems up to 600 V (690 V de-rated). The reactor provides noise reduction and electrical interference mitigation in demanding environments.\u003cul\u003e\n\u003cli\u003eAmperage: 720 A\u003c\/li\u003e\n\u003cli\u003eVoltage: 480 V (600 V de-rated)\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eHorsepower Rating: 600 HP\u003c\/li\u003e\n\u003cli\u003eImpedance: 3%\u003c\/li\u003e\n\u003cli\u003eSeries: Centurion R\u003c\/li\u003e\n\u003cli\u003eConstruction: Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003cli\u003eDimensions: 13.75 x 11.63 x 14.5 inches\u003c\/li\u003e\n\u003cli\u003eWeight: 145 lbs\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: CRX0720AC\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Core \u0026amp; Coil\u003c\/li\u003e\n\u003cli\u003eRated Current : 720A\u003c\/li\u003e\n\u003cli\u003eWatts Loss (NPL) : 480W\u003c\/li\u003e\n\u003cli\u003eReactor Dimensions : 14.5in\/369mm(H), 13.75in\/350mm(W), 11.63in\/296mm(D)\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423119133\u003c\/li\u003e\n\u003cli\u003eWeight : 145 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/CRX0720AC\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Control_and_Automation\/HPS-Centurion-R-Reactor-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205222289567,"sku":"CRX0720AC-New","price":2184.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/CRX0720AC.jpg?v=1757542474"},{"product_id":"sg3a0045dk","title":"SG3A0045DK - Hammond Power Solutions 45kVA 3-Phase 240D-480Y\/277V Aluminum Wound NEMA 3R Distribution Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3A0045DK\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eSG3A0045DK\u003c\/b\u003e is a 45kVA, 3-phase, energy-efficient distribution transformer designed for general purpose power applications. This unit features a robust NEMA 3R enclosure and is built for reliable performance in demanding environments.Engineered for 60 Hz operation, the SG3A0045DK offers a 240V delta primary and a 480Y\/277V secondary configuration, making it suitable for a wide range of commercial and industrial applications. The transformer is constructed with aluminum windings and a heavy-duty ventilated Type 3R enclosure, providing protection against dust and water ingress. It is compliant with DOE 2016 and NRCan 2019 efficiency standards and is designed for floor or wall mounting.\u003cul\u003e\n\u003cli\u003e45kVA power rating\u003c\/li\u003e\n\u003cli\u003e3-phase configuration\u003c\/li\u003e\n\u003cli\u003e240V delta primary\u003c\/li\u003e\n\u003cli\u003e480Y\/277V secondary\u003c\/li\u003e\n\u003cli\u003eAluminum wound\u003c\/li\u003e\n\u003cli\u003e60 Hz frequency\u003c\/li\u003e\n\u003cli\u003eNEMA 3R enclosure\u003c\/li\u003e\n\u003cli\u003eEnergy efficient, DOE 2016 and NRCan 2019 compliant\u003c\/li\u003e\n\u003cli\u003eFloor or wall mounting\u003c\/li\u003e\n\u003cli\u003eHeavy-duty ventilated enclosure\u003c\/li\u003e\n\u003cli\u003eUL and CSA approved\u003c\/li\u003e\n\u003cli\u003e25.8\" W x 23.8\" D x 28.8\" H\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3A0045DK\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Distribution Equipment\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Transformers\u003c\/li\u003e\n\u003cli\u003eSection  : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Sentinel G\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 45\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH2-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 28.75in\/731mm(H), 25.75in\/655mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 45\u003c\/li\u003e\n\u003cli\u003eVector Configuration : YNd1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423123321\u003c\/li\u003e\n\u003cli\u003eDimensions : 28.8 in H x 25.8 in W x 23.8 in D\u003c\/li\u003e\n\u003cli\u003eWeight : 345 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205312598175,"sku":"SG3A0045DK-New","price":3950.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3A0045DK.jpg?v=1757544275"},{"product_id":"sg3a0075kb","title":"SG3A0075KB - Hammond Power Solutions 75 kVA 3-Phase 480V Delta to 208Y\/120V Dry Type Transformer NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3A0075KB\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eSG3A0075KB\u003c\/b\u003e is a 75 kVA, 3-phase dry type transformer from Hammond Power Solutions designed for general-purpose power distribution.This transformer features a primary voltage of 480V Delta and a secondary voltage of 208Y\/120V, operating at 60 Hz frequency. It is housed in a NEMA 3R ventilated enclosure suitable for indoor or outdoor use, with a 150¡C temperature rise and aluminum windings. The robust core and coil interface enhances short circuit performance. It meets the latest energy efficiency standards set by DOE and NRCan and is UL listed and CSA certified.\u003cul\u003e\n\u003cli\u003ePower Rating: 75 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: 3-Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 480V Delta\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 208Y\/120V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R ventilated\u003c\/li\u003e\n\u003cli\u003eTemperature Rise: 150¡C\u003c\/li\u003e\n\u003cli\u003eConductor Material: Aluminum windings\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003cli\u003eMounting Type: Floor Mount\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3A0075KB\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Distribution Equipment\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Transformers\u003c\/li\u003e\n\u003cli\u003eSection  : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Sentinel G\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 208Y\/120\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 75\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 36in\/915mm(H), 28.25in\/718mm(W), 27in\/686mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 75\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dyn1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423121969\u003c\/li\u003e\n\u003cli\u003eDimensions : 27 in L x 28.3 in W x 36 in H 36 in H x 28.3 in W x 27 in D\u003c\/li\u003e\n\u003cli\u003eWeight : 575 lb\u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205312729247,"sku":"SG3A0075KB-New","price":4144.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3A0075KB_1.jpg?v=1757539188"},{"product_id":"sg3c0045kd","title":"Hammond Power Solutions SG3C0045KD - Dry Type Transformer 45 kVA (480D-240\/120V)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3C0045KD\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3C0045KD is a dry-type distribution transformer designed for industrial power distribution applications. This 45 kVA three-phase transformer features a 480V delta primary and 240\/120V secondary configuration with aluminum windings rated for 150å¡C temperature rise and 220å¡C insulation class. The unit is housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 28.75 inches high by 25.75 inches wide by 23.8 inches deep, and operates at a quiet 45 dBA sound level. It complies with DOE 2016, NRCAN 2019, and NMX 2021 efficiency regulations while meeting seismic standards including OSHPD and IBC 2018 with Sds=2.0, z\/h=1, and lp=1.5 parameters. Typical applications include industrial facilities, commercial buildings, and infrastructure projects requiring reliable power transformation with seismic resilience.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Dry-Type Distribution Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 480V Delta Primary, 240\/120V Secondary\u003c\/li\u003e \u003cli\u003eCurrent: 45 kVA Capacity\u003c\/li\u003e \u003cli\u003ePhase: 3-Phase\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150å¡C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220å¡C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 28.75\" H ÌÑ 25.75\" W ÌÑ 23.8\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5%\u003c\/li\u003e \u003cli\u003eEfficiency Compliance: DOE 2016, NRCAN 2019, NMX 2021\u003c\/li\u003e \u003cli\u003eSeismic Standards: OSHPD, IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3C0045KD\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Distribution Equipment\u003c\/li\u003e\n\u003cli\u003eItem Subcategory : Transformers\u003c\/li\u003e\n\u003cli\u003eSection  : Dry Type\u003c\/li\u003e\n\u003cli\u003eFamily : Sentinel G\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 240\/120\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 45\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH2-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 28.75in\/731mm(H), 25.75in\/655mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 45\u003c\/li\u003e\n\u003cli\u003eVector Configuration : Dd0 (0Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423124199\u003c\/li\u003e\n\u003cli\u003eDimensions : 23.8 in L x 25.8 in W x 28.8 in H 28.8 in H x 25.8 in W x 23.8 in D\u003c\/li\u003e\n\u003cli\u003eWeight : 374 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                          ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205314695327,"sku":"SG3C0045KD-New","price":3201.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3C0045KD_1.jpg?v=1757539259"},{"product_id":"sg3n0015le","title":"Hammond Power Solutions SG3N0015LE - Single-Phase Transformer 15 kVA (Type 3R)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3N0015LE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3N0015LE is a single-phase general duty transformer designed for industrial power distribution applications. This 15 kVA unit operates at 60Hz with primary voltage configurations of 240x480V and secondary output of 120\/240V, featuring aluminum windings rated for 150Â°C temperature rise with 220Â°C insulation class. The transformer is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 26.67\" H Ã— 22.25\" W Ã— 23.8\" D, and produces minimal 45 dBA operational noise. It complies with DOE 2016, NRCAN 2019, and NMX 2021 efficiency regulations while meeting OSHPD and IBC 2018 seismic requirements (Sds=2.0, z\/h=1, lp=1.5). Typical applications include commercial buildings, industrial facilities, and infrastructure projects requiring reliable power conversion with seismic resilience.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 240x480V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 15 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 26.67\" H Ã— 22.25\" W Ã— 23.8\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eImpedance: 3% - 6.1%\u003c\/li\u003e \u003cli\u003eCompliance: DOE 2016, NRCAN 2019, NMX 2021, OSHPD, IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3N0015LE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 15\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 3% - 6.1%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH1-1-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 26.67in\/678mm(H), 22.25in\/566mm(W), 23.8in\/605mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 15\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423140632\u003c\/li\u003e\n\u003cli\u003eWeight : 160 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3N0015LE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH1-1-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863109279,"sku":"SG3N0015LE-New","price":1925.15,"currency_code":"USD","in_stock":true},{"title":"Re-Certified","offer_id":62205319381151,"sku":"SG3N0015LE-ReCert","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3N0015LE.jpg?v=1757544677"},{"product_id":"sg3n0075le","title":"Hammond Power Solutions SG3N0075LE - Single-Phase Transformer 75 kVA (Type 3R)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3N0075LE\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3N0075LE is a single-phase general duty transformer designed for industrial power distribution applications. This 75 kVA unit features flexible primary voltage configurations of 240x480V with parallel\/series connections and delivers secondary voltage of 120\/240V, constructed with aluminum windings rated for 150Â°C temperature rise and 220Â°C insulation class. The transformer meets stringent efficiency standards including DOE 2016, NRCAN 2019, and NMX 2021, while housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish measuring 36\" H Ã— 28.25\" W Ã— 27\" D. It complies with IBC 2018 seismic requirements (Sds=2.0, z\/h=1, lp=1.5) and operates at 50 dBA sound level, making it suitable for commercial buildings, industrial facilities, and utility applications requiring reliable power conversion with standard impedance range of 3% to 6.1%.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 240x480V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 75 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 36\" H Ã— 28.25\" W Ã— 27\" D\u003c\/li\u003e \u003cli\u003eSound Level: 50 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 3% - 6.1% Standard\u003c\/li\u003e \u003cli\u003eEfficiency Compliance: DOE 2016, NRCAN 2019, NMX 2021\u003c\/li\u003e \u003cli\u003eSeismic Rating: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3N0075LE\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 75\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 3% - 6.1%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 36in\/915mm(H), 28.25in\/718mm(W), 27in\/686mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 75\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423140670\u003c\/li\u003e\n\u003cli\u003eWeight : 485 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3N0075LE\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH3-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863142047,"sku":"SG3N0075LE-New","price":5236.85,"currency_code":"USD","in_stock":true},{"title":"Re-Certified","offer_id":62205319446687,"sku":"SG3N0075LE-ReCert","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3N0075LE.jpg?v=1757544691"},{"product_id":"q005xekf","title":"Q005XEKF - Hammond Power Solutions 5kVA Single Phase Encapsulated Transformer NEMA 3R 120\/240V 208\/415V 50\/60Hz","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ005XEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ005XEKF\u003c\/b\u003e is a single phase encapsulated transformer from Hammond Power Solutions, designed for reliable power distribution in demanding environments. This unit features dual primary and secondary voltage ratings, copper windings, and a robust NEMA 3R enclosure for protection against dust and moisture. The Q005XEKF transformer is part of the HPS Titan series, engineered for use in harsh and hazardous locations. It supports parallel and series connections for flexible wiring, and is suitable for both commercial and industrial applications. The encapsulated design ensures durability and long-term performance, while the compact size allows for easy installation in tight spaces. \u003cul\u003e \u003cli\u003e5 kVA capacity\u003c\/li\u003e \u003cli\u003eSingle phase\u003c\/li\u003e \u003cli\u003eDual primary voltage: 208\/415V\u003c\/li\u003e \u003cli\u003eDual secondary voltage: 120\/240V\u003c\/li\u003e \u003cli\u003e50\/60 Hz frequency\u003c\/li\u003e \u003cli\u003eCopper windings\u003c\/li\u003e \u003cli\u003eNEMA 3R enclosure\u003c\/li\u003e \u003cli\u003eWall mounting\u003c\/li\u003e \u003cli\u003eUL Listed\u003c\/li\u003e \u003cli\u003eCSA certified\u003c\/li\u003e \u003cli\u003eABS approved\u003c\/li\u003e \u003cli\u003eMeets ANSI 61 standards\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q005XEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423033064\u003c\/li\u003e\n\u003cli\u003eWeight : 105 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q005XEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62205442719903,"sku":"Q005XEKF-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q005XEKF.jpg?v=1757544143"},{"product_id":"c1f005xes","title":"C1F005XES - Hammond Power Solutions 5 kVA 1-Phase Encapsulated Core Transformer 190-480VAC Primary 120\/240VAC Secondary NEMA 3R Wall Mount","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005XES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F005XES\u003c\/b\u003e is a Hammond Power Solutions HPS Fortress Series encapsulated core transformer designed for general purpose and commercial applications. This 5 kVA, 1-phase transformer features a selectable primary voltage range and a 120\/240 VAC secondary output, suitable for a variety of industrial and commercial power needs. The C1F005XES is built with copper windings and a robust NEMA 3R enclosure for reliable performance in demanding environments. It is wall mountable and includes electrostatic shielding for enhanced safety and noise reduction. The transformer is engineered for 50\/60 Hz operation and is UL Listed, CSA Certified, and CE Approved for international compliance. \u003cul\u003e \u003cli\u003ePart Number: C1F005XES\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eSeries: HPS Fortress\u003c\/li\u003e \u003cli\u003eRating: 5 kVA\u003c\/li\u003e \u003cli\u003ePhase: 1-Phase\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 190\/200\/208\/220\/240 x 380\/400\/416\/440\/480 VAC\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120\/240 VAC\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e \u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eWinding Material: Copper\u003c\/li\u003e \u003cli\u003eCertifications: UL Listed, CSA Certified, CE Approved\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005XES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 220x440,208x416,200x400,190x380V-120\/240V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092634\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005XES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62206562238623,"sku":"C1F005XES-New","price":1246.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F005XES_1.jpg?v=1757541020"},{"product_id":"q003xekf","title":"Q003XEKF - Hammond Power Solutions 3kVA 1PH Encapsulated Transformer NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eQ003XEKF\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eQ003XEKF\u003c\/b\u003e is a single-phase encapsulated distribution transformer rated at 3 kVA with primary voltage of 208\/415V and secondary voltage of 120\/240V, designed for harsh environments and hazardous locations. This transformer features copper windings with an insulation system rated at 115°C rise (180°C class), providing reliable performance in demanding applications. The unit is fully encapsulated with electrical grade silica sand and resin compounds to seal out moisture and contaminants, and includes an electrostatic shield for enhanced protection. \u003cb\u003eKey Specifications\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRating: 3 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 208\/415V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eInsulation Class: 180°C (115°C rise)\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eWinding Material: Copper\u003c\/li\u003e\n\u003cli\u003eUL Listed: File E258346\u003c\/li\u003e\n\u003cli\u003eEncapsulation: Electrical grade silica sand and resin\u003c\/li\u003e\n\u003cli\u003eMounting: Standard wall mounting with keyhole slots\u003c\/li\u003e\n\u003cli\u003eWarranty: 10 years\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: Q003XEKF\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty (Suitable For Some Hazardous Locations and Marine ABS Duty)\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 115Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : OSHPD, IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : Yes\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423033019\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423033019\u003c\/li\u003e\n\u003cli\u003eWeight : 105 \u003c\/li\u003e\n\u003cli\u003eCertification : cULus (Class I, Division 2, Groups A,B,C,D and Class I, Zone 2, Group IIC, T3 Hazardous Location), CE, ABS\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/Q003XEKF\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Titan-Series-Encapsulated-Transformer-for-Harsh-Environments-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62206562697375,"sku":"Q003XEKF-New","price":1147.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/Q003XEKF.jpg?v=1757544130"},{"product_id":"sg3a0112bk","title":"Hammond Power Solutions SG3A0112BK - 3-Phase Transformer 112.5 kVA (208D-480Y\/277V)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eSG3A0112BK\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions SG3A0112BK is a three-phase general duty transformer designed for industrial power distribution applications. This transformer features a 208V delta primary connection and delivers 480Y\/277V secondary voltage through its wye-N configuration, with an efficiency rating of 112.5 kVA that complies with DOE 2016, NRCAN 2019, and NMX 2021 energy efficiency regulations. Constructed with aluminum windings rated for 150Â°C temperature rise and 220Â°C insulation class, the unit is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish measuring 36\" H Ã— 28.25\" W Ã— 27\" D. The transformer meets IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and operates at 50 dBA sound levels with mechanical lug secondary terminations and standard impedance range of 2.5% to 6.5%.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Three-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 208V Delta Primary, 480Y\/277V Secondary\u003c\/li\u003e \u003cli\u003eCurrent: 112.5 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 150Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 220Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 36\" H Ã— 28.25\" W Ã— 27\" D\u003c\/li\u003e \u003cli\u003eSound Level: 50 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 2.5% - 6.5%\u003c\/li\u003e \u003cli\u003eEfficiency Compliance: DOE 2016, NRCAN 2019, NMX 2021\u003c\/li\u003e \u003cli\u003eSeismic Rating: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: SG3A0112BK\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 3\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 208D\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Delta\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 480Y\/277\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Wye-N\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 150Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 220Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 112.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : DOE 2016 (US), NRCAN 2019 (Canada), NMX 2021 (Mexico)\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 50 dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 2.5% - 6.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mechanical Lugs\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : DH3-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 36in\/915mm(H), 28.25in\/718mm(W), 27in\/686mm(D)\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 112.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : YNd1 (-30Â°)\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423122867\u003c\/li\u003e\n\u003cli\u003eWeight : 770 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/SG3A0112BK\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Sentinel-Energy-Efficient-Low-Voltage-Distribution-Selection-Guide.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/DH3-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863076511,"sku":"SG3A0112BK-New","price":8897.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/SG3A0112BK.jpg?v=1757544322"},{"product_id":"ahf-floor1","title":"Hammond Power Solutions AHF-FLOOR1 - Dry-Type Transformer 75 kVA (480V-208Y\/120V)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eAHF-FLOOR1\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions AHF-FLOOR1 is a dry-type isolation transformer designed for providing clean power and voltage transformation in demanding industrial environments. It features a primary voltage of 480V and a secondary voltage of 208Y\/120V, with a power rating of 75 kVA. The transformer is constructed with a robust, floor-mounted NEMA 3R enclosure suitable for both indoor and outdoor installations, utilizing 220Â°C insulation systems for reliable performance. This unit is UL listed and compliant with relevant industry standards for safety and performance. It is ideally suited for applications in manufacturing plants, data centers, and other facilities requiring voltage step-down and power conditioning.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e \u003cul\u003e \u003cli\u003eType: Dry-Type Isolation Transformer\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 480 V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 208Y\/120 V\u003c\/li\u003e \u003cli\u003ekVA Rating: 75 kVA\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eInsulation System: 220Â°C\u003c\/li\u003e \u003cli\u003eMounting: Floor\u003c\/li\u003e \u003cli\u003eStandards: UL Listed\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: AHF-FLOOR1\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eWeight : 600 \u003c\/li\u003e\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/AHF-FLOOR1\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863240351,"sku":"AHF-FLOOR1-New","price":989.49,"currency_code":"USD","in_stock":true}]},{"product_id":"ahf-floor2","title":"Hammond Power Solutions AHF-FLOOR2 - Dry-Type Transformer 45 kVA 480V-208Y\/120V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eAHF-FLOOR2\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions AHF-FLOOR2 is a dry-type isolation transformer designed for providing clean power and voltage transformation in industrial environments. It features a 480V primary and 208Y\/120V secondary configuration with a robust 45 kVA power rating, engineered for reliable performance under demanding conditions. The transformer utilizes a core and coil assembly with 220Â°C insulation system housed in a NEMA 3R rated floor-mounting enclosure suitable for indoor\/outdoor installation. This unit is UL listed and compliant with industry standards including CSA C22.2 No. 66 for safety and performance assurance. Typical applications include industrial machinery, manufacturing facilities, and commercial power distribution systems requiring voltage step-down transformation.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Dry-Type Isolation Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 480V Primary, 208Y\/120V Secondary\u003c\/li\u003e \u003cli\u003ePower Rating: 45 kVA\u003c\/li\u003e \u003cli\u003eEnclosure Rating: NEMA 3R\u003c\/li\u003e \u003cli\u003eInsulation System: 220Â°C\u003c\/li\u003e \u003cli\u003eMounting: Floor Mount\u003c\/li\u003e \u003cli\u003eStandards: UL Listed, CSA C22.2 No. 66\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: AHF-FLOOR2\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : N \/ A\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eWeight : 1600 \u003c\/li\u003e\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/AHF-FLOOR2\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863273119,"sku":"AHF-FLOOR2-New","price":929.64,"currency_code":"USD","in_stock":true}]},{"product_id":"c1f002hrs","title":"Hammond Power Solutions C1F002HRS - Transformer 2kVA 480\/277V-277\/208V Copper","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F002HRS\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F002HRS is a single-phase general duty transformer designed for industrial power distribution applications. This 2 kVA unit features versatile voltage conversion with primary inputs of 480V\/277V and secondary outputs of 277V\/208V, operating at 50\/60Hz frequency with copper windings rated for 135Â°C temperature rise and 180Â°C insulation class. The transformer is housed in a compact Type 3R\/IP24 enclosure measuring 11.75Ã—7.06Ã—6.25 inches with ANSI 61 grey finish, providing outdoor protection while maintaining a low 45dBA sound level. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features UL50 listed construction with 1-5% impedance and series-connected primary and secondary windings. Typical applications include commercial lighting systems, industrial control circuits, and power distribution where voltage transformation between 480V\/277V and 208V systems is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 480\/277V, Secondary 277\/208V\u003c\/li\u003e \u003cli\u003eCurrent: 2 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" H Ã— 7.06\" W Ã— 6.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1-5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F002HRS\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 2kVA 480,277V-277,208V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 2\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads, Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 2\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : None\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092733\u003c\/li\u003e\n\u003cli\u003eWeight : 53 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F002HRS\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863371423,"sku":"C1F002HRS-New","price":611.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F002HRS.jpg?v=1757541035"},{"product_id":"c1f002wes","title":"Hammond Power Solutions C1F002WES - 2 kVA Transformer 277\/240\/208\/120V-120\/240V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F002WES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F002WES is a general duty transformer designed for industrial power distribution applications. This single-phase 2 kVA unit features versatile primary voltage compatibility (277V, 240V, 208V, or 120V) with secondary output configurable for 120\/240V operation. Constructed with copper windings and housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, the transformer measures 11.75\" H Ã— 7.06\" W Ã— 6.25\" D and operates with a 135Â°C temperature rise and 180Â°C insulation class. The unit complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and maintains a 45 dBA sound level per NEMA ST-20. Typical applications include commercial lighting, control circuits, and industrial equipment power supply where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 277\/240\/208\/120V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 2 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5% standard\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24 rated\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" H Ã— 7.06\" W Ã— 6.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F002WES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 2kVA 277,240,208,120V-120\/240V  60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277, 240, 208, 120\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 2\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 2\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092726\u003c\/li\u003e\n\u003cli\u003eWeight : 50 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F002WES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863502495,"sku":"C1F002WES-New","price":643.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F002WES_1.jpg?v=1757541016"},{"product_id":"c1f002xes","title":"C1F002XES - Hammond Power Solutions 2 kVA 1-Phase NEMA 3R Wall Mount Transformer 190-480 VAC Primary 120\/240 VAC Secondary","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F002XES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F002XES\u003c\/b\u003e is a general purpose encapsulated core transformer designed for commercial and industrial applications. This unit features a robust NEMA 3R enclosure and is suitable for wall mounting, providing reliable power distribution in demanding environments. The C1F002XES transformer is built with a copper winding and includes an electrostatic shield for improved noise reduction and safety. It supports a wide range of primary voltages and delivers a stable 120\/240 VAC secondary output, making it versatile for various electrical systems. The unit is rated for 50\/60 Hz operation and is designed for single-phase service. \u003cul\u003e \u003cli\u003e2 kVA power rating\u003c\/li\u003e \u003cli\u003e1-phase configuration\u003c\/li\u003e \u003cli\u003ePrimary voltage: 190-480 VAC selectable\u003c\/li\u003e \u003cli\u003eSecondary voltage: 120\/240 VAC\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e \u003cli\u003eMounting type: Wall mount\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eElectrostatically shielded\u003c\/li\u003e \u003cli\u003eCopper winding\u003c\/li\u003e \u003cli\u003eDimensions: 11.75 in H x 7 in W x 6.5 in D\u003c\/li\u003e \u003cli\u003eUL, CSA, CE certified\u003c\/li\u003e \u003cli\u003eImpedance: Typically 4 to 8%\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F002XES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 2kVA 220x440,208x416,200x400,190x380V-120\/240V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 2\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 2\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090906\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423090906\u003c\/li\u003e\n\u003cli\u003eWeight : 52 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F002XES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863535263,"sku":"C1F002XES-New","price":684.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F002XES_1.jpg?v=1757541017"},{"product_id":"c1f003ces","title":"Hammond Power Solutions C1F003CES - Transformer 3kVA 277V-120\/240V Copper","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003CES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F003CES is a general duty single-phase transformer designed for industrial power distribution applications. This 3 kVA unit features a primary voltage of 277V with series connection and a secondary voltage of 120\/240V with parallel\/series-N configuration, constructed with copper windings and operating at 50\/60Hz frequency. The transformer is housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 11.75 inches in height, 7.06 inches in width, and 6.25 inches in depth, and maintains a low sound level of 45dBA. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features 135Â°C temperature rise with 180Â°C insulation class. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: 277V primary, 120\/240V secondary\u003c\/li\u003e \u003cli\u003eCurrent: 3 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" H Ã— 7.06\" W Ã— 6.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003CES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 277V-120\/240V 50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092467\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423092467\u003c\/li\u003e\n\u003cli\u003eWeight : 55 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003CES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863568031,"sku":"C1F003CES-New","price":775.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003CES.jpg?v=1757541040"},{"product_id":"c1f003ees","title":"C1F003EES - Hammond Power Solutions 3 kVA 1-Phase 120\/240V Distribution Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003EES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F003EES\u003c\/b\u003e is a single-phase encapsulated distribution transformer rated at 3 kVA with 120\/240 V AC primary and secondary voltages, designed for commercial and light industrial applications. \u003cb\u003ePart Number C1F003EES\u003c\/b\u003e features the HPS Fortress series construction with all-welded core design using high-permeability silicon steel laminations and copper windings. The unit is housed in a NEMA 3R indoor\/outdoor enclosure with ANSI 61 gray finish, wall-mounted configuration, and lead wire connections suitable for shopping centers, schools, sports complexes, and wastewater treatment facilities. \u003cb\u003eKey Specifications\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003ePower Rating: 3 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase (1 ph)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 120\/240 V AC\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 V AC\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: NEMA 3R Indoor\/Outdoor\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e\n\u003cli\u003eConnection: Lead Wire\/Tab\u003c\/li\u003e\n\u003cli\u003eCore Construction: All-welded with silicon steel laminations\u003c\/li\u003e\n\u003cli\u003eWinding Material: Copper\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003cli\u003eDimensions: 6.5 in L x 7 in W x 11.75 in H\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003EES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 120x240V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120x240\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092283\u003c\/li\u003e\n\u003cli\u003eWeight : 55 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003EES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863666335,"sku":"C1F003EES-New","price":684.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003EES.jpg?v=1757541042"},{"product_id":"c1f003ges","title":"Hammond Power Solutions C1F003GES - Transformer 3kVA 208x416V-120\/240V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003GES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F003GES is a general purpose transformer designed for industrial power distribution applications. This single-phase 3 kVA unit features versatile voltage configurations with a primary of 208x416V and secondary of 120\/240V, constructed with copper windings for reliable performance. The transformer is housed in a compact Type 3R\/IP24 rated enclosure measuring 11.75\" x 7.06\" x 6.25\" with ANSI 61 grey finish, providing protection against weather conditions. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and operates with a low 45 dBA sound level per NEMA ST-20. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where flexible voltage conversion is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 208x416V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 3 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" H x 7.06\" W x 6.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003GES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 208x416V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 208x416\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092375\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423092375\u003c\/li\u003e\n\u003cli\u003eWeight : 55 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003GES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863699103,"sku":"C1F003GES-New","price":684.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003GES.jpg?v=1757541043"},{"product_id":"c1f003hrs","title":"C1F003HRS - Hammond Power Solutions 3kVA Single Phase 277\/480V to 208\/277V NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003HRS\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F003HRS\u003c\/b\u003e is a single phase potted distribution transformer rated 3kVA with primary voltage of 277\/480V and secondary voltage of 208\/277V, designed for commercial applications in a NEMA 3R enclosure. This HPS Fortress encapsulated transformer features a heavy-duty Type 3R enclosure and is completely encapsulated with electrical grade silica sand and resin compounds to seal out moisture and contaminants. The unit includes standard wall mounting capability and front-accessible copper lead wire termination for easy installation and maintenance. \u003cul\u003e\n\u003cli\u003eCapacity: 3kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 277\/480V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 208\/277V\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eMounting: Wall Mount\u003c\/li\u003e\n\u003cli\u003eInsulation System: 180°C (115°C rise)\u003c\/li\u003e\n\u003cli\u003eEncapsulation: Electrical grade silica sand and resin\u003c\/li\u003e\n\u003cli\u003eTermination: Front accessible copper leads\u003c\/li\u003e\n\u003cli\u003eUL Listed File E50394\u003c\/li\u003e\n\u003cli\u003eCSA Certified\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003HRS\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 480,277V-277,208V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads, Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : None\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423093914\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003HRS\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863731871,"sku":"C1F003HRS-New","price":775.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003HRS.jpg?v=1757541047"},{"product_id":"c1f003jes","title":"C1F003JES - Hammond Power Solutions 3 kVA 347\/380V to 120\/240V Single Phase Commercial Potted Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003JES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F003JES\u003c\/b\u003e is a Hammond Power Solutions Fortress™ commercial potted distribution transformer with a 3 kVA power rating.\u003cp\u003eThis single-phase transformer features primary voltages of 347\/380 VAC and secondary voltages of 120\/240 VAC, operating at 50\/60 Hz frequency. It is designed for commercial applications with encapsulated construction for durability and reliability. The unit includes front-accessible separated high and low voltage lead wires or mounting pads, with rear and side conduit entry. Standard wall mounting is provided, and the transformer meets UL and CSA certifications.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower Rating: 3 kVA\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 347\/380 VAC\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Type: Standard Wall Mount\u003c\/li\u003e\n\u003cli\u003eEnclosure: Potted (Encapsulated)\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003cli\u003eDimensions: Approximately 10.00\" W x 7.75\" D x 17.25\" H\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 98 lbs\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time.\u003c\/p\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003JES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 380,347V-120\/240V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 380, 347\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090791\u003c\/li\u003e\n\u003cli\u003eWeight : 98 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003JES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863764639,"sku":"C1F003JES-New","price":775.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003JES.jpg?v=1757541045"},{"product_id":"c1f003les","title":"C1F003LES - Hammond Power Solutions 3 kVA 1-Phase 240\/480V to 120\/240V NEMA 3R Wall Mount Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003LES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F003LES\u003c\/b\u003e is a 3 kVA, single-phase encapsulated distribution transformer from Hammond Power Solutions' HPS Fortress series designed for commercial applications.\u003cb\u003e \u003c\/b\u003e This transformer features a NEMA 3R rated enclosure suitable for indoor and outdoor use, with primary voltages of 240 and 480 V and secondary voltages of 120 and 240 V. It is wall mountable and encapsulated with electrical grade silica sand and resin compounds to protect against moisture and contaminants.\u003cb\u003e \u003c\/b\u003e \u003cul\u003e \u003cli\u003ePower Rating: 3,000 VA (3 kVA)\u003c\/li\u003e \u003cli\u003ePhase: Single-phase (1 ph)\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 240 V, 480 V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120 V, 240 V\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eMounting Type: Wall mount\u003c\/li\u003e \u003cli\u003eEnclosure Rating: NEMA 3R\u003c\/li\u003e \u003cli\u003eInsulation Class: Class H\u003c\/li\u003e \u003cli\u003eWeight: Approximately 51.9 lbs net\u003c\/li\u003e \u003cli\u003eSeries: HPS Fortress\u003c\/li\u003e \u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003LES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 240x480V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090746\u003c\/li\u003e\n\u003cli\u003eWeight : 51 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003LES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863797407,"sku":"C1F003LES-New","price":622.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003LES.jpg?v=1757541051"},{"product_id":"c1f003pes","title":"Hammond Power Solutions C1F003PES - Transformer 3kVA 600V-120\/240V Copper","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003PES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F003PES is a general duty transformer designed for industrial power distribution applications. This single-phase unit features a 600V primary with series connection and a 120\/240V secondary with parallel\/series-N configuration, delivering 3kVA capacity with copper windings rated for 135Â°C temperature rise and 180Â°C insulation class. The transformer is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 11.75\" H Ã— 7.06\" W Ã— 6.25\" D, and operates at 45dBA with 1-5% impedance. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and NEMA ST-20 sound requirements. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is critical.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: 600V primary, 120\/240V secondary\u003c\/li\u003e \u003cli\u003eCurrent: 3kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 11.75\" Ã— 7.06\" Ã— 6.25\" (299mm Ã— 180mm Ã— 159mm)\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e \u003cli\u003eSecondary Termination: Wire leads\u003c\/li\u003e \u003cli\u003eElectrostatic Shield: Single\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003PES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 600V-120\/240V 60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 600\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ4-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 11.75in\/299mm(H), 7.06in\/180mm(W), 6.25in\/159mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090852\u003c\/li\u003e\n\u003cli\u003eWeight : 55 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003PES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ4-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863830175,"sku":"C1F003PES-New","price":652.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003PES.jpg?v=1757541049"},{"product_id":"c1f003wes","title":"C1F003WES - Hammond Power Solutions 3 kVA 1-Phase Wall Mount Encapsulated Transformer 120\/208\/240\/277V Primary 120\/240V Secondary","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003WES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F003WES\u003c\/b\u003e is a 3 kVA single-phase encapsulated transformer designed for wall mounting by Hammond Power Solutions.This transformer features multiple primary voltage taps of 120, 208, 240, and 277 volts with a 120\/240 volts secondary output. It operates at 60 Hz frequency and is UL and CSA certified. The unit is encapsulated for durability and suitable for commercial and industrial applications requiring reliable voltage isolation and conversion.\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 3 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single-phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 120\/208\/240\/277 V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 V\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall mount\u003c\/li\u003e\n\u003cli\u003eEncapsulation: Encapsulated isolation type\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003WES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 277,240,208,120V-120\/240V  60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277, 240, 208, 120\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPC : 803423093907\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423093907\u003c\/li\u003e\n\u003cli\u003eWeight : 86 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003WES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/ul\u003e","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863862943,"sku":"C1F003WES-New","price":805.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003WES_1.jpg?v=1757541017"},{"product_id":"c1f003xes","title":"Hammond Power Solutions C1F003XES - Single-Phase Transformer 3kVA (Type 3R\/IP24)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F003XES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F003XES is a general duty single-phase transformer designed for industrial power distribution applications. This 3kVA transformer features versatile voltage configurations with primary voltages of 120\/240V or 130\/262V and secondary voltages of 120\/240V or 130\/262V, operating at 50\/60Hz frequency with copper windings and 1-5% impedance. The unit is housed in a Type 3R\/IP24 rated enclosure with ANSI 61 Grey finish, measuring 17.25 inches high by 10 inches wide by 7.75 inches deep, and features a 135Â°C temperature rise with 180Â°C insulation class. Compliant with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and UL50 requirements, it maintains a low 45dBA sound level per NEMA ST-20. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 120\/240V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 3kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Copper Windings\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H Ã— 10\" W Ã— 7.75\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1-5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F003XES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 3kVA 220x440,208x416,200x400,190x380V-120\/240V  50\/60Hz CU\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz,60Hz(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240,130\/262(1)\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Copper\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 3\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 3\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423090913\u003c\/li\u003e\n\u003cli\u003eWeight : 65 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F003XES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863895711,"sku":"C1F003XES-New","price":857.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F003XES_1.jpg?v=1757541019"},{"product_id":"c1f005ces","title":"C1F005CES - Hammond Power Solutions 1ph 5kVA 277V-120\/240V NEMA 3R Encapsulated Isolation Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005CES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F005CES\u003c\/b\u003e is a single-phase encapsulated isolation transformer designed for commercial and industrial applications requiring reliable voltage transformation and protection against environmental contaminants.Manufactured by Hammond Power Solutions, this Fortress series transformer features a robust NEMA 3R enclosure, making it suitable for indoor and outdoor installations. The unit is encapsulated in epoxy and silica for enhanced durability and moisture resistance, ensuring long operational life. It provides a primary voltage of 277V and secondary output of 120\/240V, ideal for a variety of power distribution needs. The transformer is wall-mountable and includes front-accessible lead wires for easy installation and maintenance.\u003cul\u003e\n\u003cli\u003ePart Number: C1F005CES\u003c\/li\u003e\n\u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eSeries: Fortress\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003eRating: 5kVA\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 277V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eConstruction: Encapsulated (Epoxy \u0026amp; Silica)\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005CES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 277V-120\/240V 50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091569\u003c\/li\u003e\n\u003cli\u003eWeight : 115 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005CES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863928479,"sku":"C1F005CES-New","price":1117.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F005CES.jpg?v=1757541054"},{"product_id":"c1f005ees","title":"C1F005EES - Hammond Power Solutions 5 kVA 1-Phase Encapsulated Distribution Transformer 120x240V Primary 120\/240V Secondary NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005EES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F005EES\u003c\/b\u003e is a 5 kVA 1-phase encapsulated distribution transformer from Hammond Power Solutions designed for reliable voltage transformation in commercial and industrial applications.This transformer features a 120 x 240-volt primary and 120\/240-volt secondary voltage configuration, suitable for single-phase power distribution. It is encapsulated for enhanced durability and protection, with a NEMA 3R enclosure rating for outdoor and indoor use. The unit measures approximately 10 inches wide, 7.75 inches deep, and 17.25 inches high, and is UL 50 and CSA approved, meeting ANSI 61 and NEMA ST-20 standards. It operates at 60 Hz frequency and is designed for wall mounting.\u003cul\u003eKey Specifications\u003cul\u003e\n\u003cli\u003ePower Rating: 5 kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single-phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 120 x 240 V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 V\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall mount\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (WxDxH): 10 x 7.75 x 17.25 inches\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, CSA, ANSI 61, NEMA ST-20\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005EES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 120x240V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120x240\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUPC : 803423091484\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091484\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005EES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e \u003c\/ul\u003e","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863961247,"sku":"C1F005EES-New","price":979.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-c1f005ees-hammond-power-solutions-5-kva-1-phase-encapsulated-distribution-transformer-120x240v-primary-120-240v-secondary-nema-3r-53687839293599.jpg?v=1766010898"},{"product_id":"c1f005ges","title":"Hammond Power Solutions C1F005GES - 5kVA Transformer 208x416V-120\/240V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005GES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F005GES is a general duty transformer designed for industrial power distribution applications. This single-phase 5 kVA unit features flexible primary voltage input of 208x416V with parallel\/series connection capability and delivers secondary output of 120\/240V. Constructed with aluminum windings and housed in a Type 3R\/IP24 rated enclosure measuring 17.25\" x 10\" x 7.75\" with ANSI 61 grey finish, the transformer operates with 135Â°C temperature rise and 180Â°C insulation class. The unit complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and maintains a quiet 45 dBA sound level per NEMA ST-20. Typical applications include commercial buildings, industrial facilities, and equipment requiring voltage transformation with outdoor environmental protection.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 208x416V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 5 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H x 10\" W x 7.75\" D\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005GES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 208x416V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 208x416\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092382\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423092382\u003c\/li\u003e\n\u003cli\u003eWeight : 115 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005GES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208863994015,"sku":"C1F005GES-New","price":979.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-c1f005ges-5kva-transformer-208x416v-120-240v-53687839359135.jpg?v=1766010898"},{"product_id":"c1f005hrs","title":"Hammond Power Solutions C1F005HRS - Transformer 5kVA 480V-208V Aluminum","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005HRS\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F005HRS is a general duty single-phase transformer designed for voltage conversion applications in industrial environments. This 5 kVA transformer features primary voltages of 480\/277V and secondary voltages of 277\/208V with series connections, constructed with aluminum windings rated for 135Â°C temperature rise and 180Â°C insulation class. The unit is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 17.25 inches high by 10 inches wide by 7.75 inches deep, and operates at a quiet 45 dBA sound level. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and NEMA ST-20 requirements for reliable performance. Typical applications include industrial control systems, lighting circuits, and power distribution where voltage step-down is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 480\/277V, Secondary 277\/208V\u003c\/li\u003e \u003cli\u003eCurrent: 5 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5% Standard\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H Ã— 10\" W Ã— 7.75\" D\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005HRS\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 480,277V-277,208V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : None\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091514\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005HRS\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864026783,"sku":"C1F005HRS-New","price":1117.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-c1f005hrs-transformer-5kva-480v-208v-aluminum-53687839391903.jpg?v=1766010898"},{"product_id":"c1f005jes","title":"Hammond Power Solutions C1F005JES - Transformer 5kVA 380\/347V-120\/240V Aluminum","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005JES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F005JES is a general duty transformer designed for industrial power distribution applications. This single-phase 5 kVA unit features primary voltages of 380\/347V and secondary voltages of 120\/240V with 50\/60Hz frequency compatibility. Constructed with aluminum windings and housed in a Type 3R\/IP24 enclosure measuring 17.25x10x7.75 inches with ANSI 61 grey finish, it operates with a 135Â°C temperature rise and 180Â°C insulation class. The transformer meets IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and maintains a low 45 dBA sound level per NEMA ST-20. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 380\/347V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 5 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H x 10\" W x 7.75\" D\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 1-5% standard\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005JES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 380,347V-120\/240V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 380, 347\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091453\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005JES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864059551,"sku":"C1F005JES-New","price":1117.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F005JES.jpg?v=1757541059"},{"product_id":"c1f005les","title":"C1F005LES - Hammond Power Solutions 5kVA 1-Phase 240\/480V Primary NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005LES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cp\u003e\u003cb\u003eC1F005LES\u003c\/b\u003e is a single-phase encapsulated core distribution transformer rated 5kVA with 240\/480 VAC primary voltage and 120\/240 VAC secondary voltage for commercial and light industrial applications.\u003c\/p\u003e\u003cp\u003eThis wall-mounted transformer features an innovative potted design with a hinged cover providing single screw access to the wiring compartment. The totally enclosed construction seals out moisture and airborne contaminants. Rear and side entry conduit knockouts lead to an easily accessible wiring compartment. The unit includes keyhole mounting slots and a supplied wall mounting template for quick installation. All welded core construction uses high-quality, high-permeability silicon steel laminations with copper or aluminum windings. An electrostatic shield is standard. The NEMA 3R enclosure meets or exceeds NEMA and ANSI standards for indoor and outdoor applications, with NEMA 4\/12 rating available when an optional gasket kit is installed.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower Rating: 5kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase (1-Phase)\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 240\/480 VAC\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: NEMA 3R\u003c\/li\u003e\n\u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e\n\u003cli\u003eCore Construction: All Welded, Silicon Steel Laminations\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield: Standard\u003c\/li\u003e\n\u003cli\u003eDimensions: 10 in W x 7.75 in D x 17.25 in H\u003c\/li\u003e\n\u003cli\u003eApproximate Weight: 115 lbs\u003c\/li\u003e\n\u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time.\u003c\/p\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005LES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 240x480V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091354\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091354\u003c\/li\u003e\n\u003cli\u003eWeight : 110 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005LES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864092319,"sku":"C1F005LES-New","price":898.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-c1f005les-hammond-power-solutions-5kva-1-phase-240-480v-primary-nema-3r-53615338094751.jpg?v=1766010899"},{"product_id":"c1f005pes","title":"Hammond Power Solutions C1F005PES - Transformer 5kVA 600V-120\/240V Aluminum","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005PES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F005PES is a general duty transformer designed for industrial power distribution applications. This single-phase unit provides 5 kVA capacity with 600V primary to 120\/240V secondary voltage conversion, featuring aluminum windings rated for 135Â°C temperature rise and 180Â°C insulation class. The transformer is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 17.25 inches high by 10 inches wide by 7.75 inches deep, and operates at a quiet 45 dBA sound level. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and meets NEMA ST-20 requirements for reliable performance in demanding environments. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where robust construction and seismic compliance are essential.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: 600V Primary to 120\/240V Secondary\u003c\/li\u003e \u003cli\u003eCurrent: 5 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H Ã— 10\" W Ã— 7.75\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003cli\u003eSecondary Termination: Wire Leads\u003c\/li\u003e \u003cli\u003eElectrostatic Shield: Single\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005PES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 600V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 600\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Wire Leads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : None\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091408\u003c\/li\u003e\n\u003cli\u003eWeight : 120 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005PES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864125087,"sku":"C1F005PES-New","price":938.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F005PES.jpg?v=1757541060"},{"product_id":"c1f005wes","title":"Hammond Power Solutions C1F005WES - Transformer 5kVA 120\/240V (Type 3R Enclosure)","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F005WES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F005WES is a general duty single-phase transformer designed for industrial power distribution applications. This 5 kVA unit features versatile primary voltage compatibility with 277V, 240V, 208V, and 120V inputs, delivering secondary outputs of 120\/240V through parallel\/series-N connections. Constructed with aluminum windings and housed in a Type 3R\/IP24 rated enclosure measuring 17.25\" x 10\" x 7.75\" with ANSI 61 grey finish, the transformer operates with 135Â°C temperature rise and 180Â°C insulation class. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and maintains a quiet 45 dBA sound level per NEMA ST-20. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 277\/240\/208\/120V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 5 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5.1%\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R \/ IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.25\" H Ã— 10\" W Ã— 7.75\" D\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F005WES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 5kVA 277,240,208,120V-120\/240V  60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277, 240, 208, 120\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5.1%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ5-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.25in\/439mm(H), 10in\/254mm(W), 7.75in\/197mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads, Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092559\u003c\/li\u003e\n\u003cli\u003eWeight : 150 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F005WES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ5-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864157855,"sku":"C1F005WES-New","price":1157.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F005WES_1.jpg?v=1757541019"},{"product_id":"c1f007ces","title":"C1F007CES - Hammond Power Solutions 7.5kVA 277V Single Phase Potted Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007CES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F007CES\u003c\/b\u003e is a 7.5kVA single phase potted transformer designed for commercial applications with primary voltage of 277V and secondary voltage of 120\/240V. This encapsulated distribution transformer features aluminum construction with Type 3R enclosure rating, providing protection suitable for indoor and outdoor environments. The unit is wall-mounted and operates at 50\/60Hz frequency, making it versatile for various electrical distribution needs.\u003cul\u003e\n\u003cli\u003eCapacity: 7.5kVA\u003c\/li\u003e\n\u003cli\u003ePhase: Single Phase\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage: 277V\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e\n\u003cli\u003eEnclosure Type: Type 3R\u003c\/li\u003e\n\u003cli\u003eConstruction: Potted Aluminum\u003c\/li\u003e\n\u003cli\u003eFrequency: 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eMounting: Wall Mount\u003c\/li\u003e\n\u003cli\u003eDimensions: 12.25 inches W x 9.25 inches D x 17.63 inches H\u003c\/li\u003e\n\u003cli\u003eWeight: Approximately 162 lbs\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, CSA Approval, ANSI 61, NEMA ST-20\u003c\/li\u003e\n\u003cli\u003eImpedance: Typically 4 to 8 percent\u003c\/li\u003e\n\u003c\/ul\u003eAt \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007CES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 277V-120\/240V 50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6A-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.63in\/448mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091576\u003c\/li\u003e\n\u003cli\u003eWeight : 170 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007CES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6A-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864190623,"sku":"C1F007CES-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F007CES.jpg?v=1757541062"},{"product_id":"c1f007ees","title":"C1F007EES - Hammond Power Solutions 7.5kVA 120\/240-120\/240 Single Phase Wall Mount NEMA 3R Encapsulated Transformer","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007EES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F007EES\u003c\/b\u003e is a single phase encapsulated transformer from Hammond Power Solutions, designed for reliable power distribution in commercial and industrial applications. This unit features a robust NEMA 3R enclosure for protection against dust and moisture, making it suitable for demanding environments. The C1F007EES transformer is rated at 7.5kVA with primary and secondary voltages of 120\/240V, providing flexible configuration for various electrical needs. It is wall mountable and constructed with aluminum windings for efficient performance and durability. The encapsulated design ensures protection against airborne particles and moisture, reducing the risk of operational interruptions. \u003cul\u003e \u003cli\u003ePart Number: C1F007EES\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eType: Encapsulated Transformer\u003c\/li\u003e \u003cli\u003ePhase: Single Phase\u003c\/li\u003e \u003cli\u003ekVA Rating: 7.5kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 120\/240V\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120\/240V\u003c\/li\u003e \u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eFrequency: 60 Hz\u003c\/li\u003e \u003cli\u003eWinding Material: Aluminum\u003c\/li\u003e \u003cli\u003eSeries: HPS Fortress\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007EES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 120x240V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 120x240\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6A-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.63in\/448mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091491\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091491\u003c\/li\u003e\n\u003cli\u003eWeight : 160 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007EES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6A-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864223391,"sku":"C1F007EES-New","price":1466.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-c1f007ees-hammond-power-solutions-7-5kva-120-240-120-240-single-phase-wall-mount-nema-3r-encapsulated-transformer-53687839522975.jpg?v=1766010898"},{"product_id":"c1f007ges","title":"Hammond Power Solutions C1F007GES - Transformer 7.5kVA 208x416V-120\/240V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007GES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F007GES is a general purpose transformer designed for industrial power distribution applications. This single-phase unit features a 7.5 kVA capacity with flexible primary voltage configuration (208x416V) and secondary output of 120\/240V, constructed with aluminum windings rated for 135Â°C temperature rise and 180Â°C insulation class. The transformer is housed in a Type 3R\/IP24 enclosure with ANSI 61 grey finish, measuring 17.63Ã—12.25Ã—9.25 inches, and operates at a quiet 45 dBA sound level. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and NEMA ST-20 requirements, making it suitable for commercial buildings, industrial facilities, and utility applications where reliable power conversion is essential.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 208x416V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 7.5 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.63\" H Ã— 12.25\" W Ã— 9.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5%\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003cli\u003ePrimary Connection: Parallel x Series (Vx2V)\u003c\/li\u003e \u003cli\u003eSecondary Connection: Parallel\/Series-N (V\/2V)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007GES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 208x416V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 208x416\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6A-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.63in\/448mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091545\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091545\u003c\/li\u003e\n\u003cli\u003eWeight : 160 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007GES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6A-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864256159,"sku":"C1F007GES-New","price":1466.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-c1f007ges-transformer-7-5kva-208x416v-120-240v-53687839555743.jpg?v=1766010899"},{"product_id":"c1f007hrs","title":"Hammond Power Solutions C1F007HRS - Transformer 7.5kVA 480\/277V-277\/208V Aluminum","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007HRS\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F007HRS is a general duty transformer designed for industrial power distribution applications. This single-phase unit features primary voltages of 480\/277V and secondary voltages of 277\/208V with a 7.5 kVA capacity operating at 50\/60 Hz frequency. The transformer is constructed with aluminum windings and housed in a Type 3R\/IP24 rated enclosure with ANSI 61 grey finish, measuring 20.88 inches high by 12.25 inches wide by 9.25 inches deep. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features a 135Â°C temperature rise with 180Â°C insulation class. Typical applications include commercial and industrial power systems requiring reliable voltage transformation with 45 dBA sound level operation and 1-5% impedance characteristics.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-phase general duty transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 480\/277V, Secondary 277\/208V\u003c\/li\u003e \u003cli\u003eCurrent: 7.5 kVA capacity\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 20.88\" H Ã— 12.25\" W Ã— 9.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45 dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 1-5% standard\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007HRS\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 480,277V-277,208V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 480, 277\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 277, 208\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 20.88in\/531mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (Std) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary Termination (Std) : Wire Leads, Wire Leads\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423092610\u003c\/li\u003e\n\u003cli\u003eWeight : 170 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007HRS\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864288927,"sku":"C1F007HRS-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-hammond-power-solutions-c1f007hrs-transformer-7-5kva-480-277v-277-208v-aluminum-53687839588511.jpg?v=1766010899"},{"product_id":"c1f007jes","title":"C1F007JES - Hammond Power Solutions 7.5 kVA 347\/380V 120\/240V Encapsulated Potted Distribution Transformer 1 Phase NEMA 3R","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007JES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\t\u003cb\u003eC1F007JES\u003c\/b\u003e is a Hammond Power Solutions Fortress™ encapsulated potted distribution transformer designed for reliable single-phase power distribution in commercial and industrial applications. This unit features dual primary voltage capability (347V\/380V) and flexible secondary output (120V\/240V), making it suitable for a wide range of installations. The transformer is constructed with copper windings and is potted for durability and protection against environmental factors. Engineered for safety and efficiency, the C1F007JES transformer is rated for 7.5 kVA and operates at 50\/60 Hz. It is designed for wall mounting and comes in a NEMA 3R enclosure for added protection. The unit is UL Listed and CSA certified, meeting stringent safety standards for commercial use. \u003cul\u003e \u003cli\u003ePart Number: C1F007JES\u003c\/li\u003e \u003cli\u003eManufacturer: Hammond Power Solutions\u003c\/li\u003e \u003cli\u003eType: Encapsulated Potted Distribution Transformer\u003c\/li\u003e \u003cli\u003ePhase: 1 Phase\u003c\/li\u003e \u003cli\u003ePower Rating: 7.5 kVA\u003c\/li\u003e \u003cli\u003ePrimary Voltage: 347\/380 V AC\u003c\/li\u003e \u003cli\u003eSecondary Voltage: 120\/240 V AC\u003c\/li\u003e \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e \u003cli\u003eMounting Type: Wall Mount\u003c\/li\u003e \u003cli\u003eEnclosure: NEMA 3R\u003c\/li\u003e \u003cli\u003eWinding Material: Copper\u003c\/li\u003e \u003cli\u003eCertifications: UL Listed, CSA Certified\u003c\/li\u003e \u003c\/ul\u003e At \u003cb\u003eEssential Parts\u003c\/b\u003e, we offer \u003cb\u003efast shipping\u003c\/b\u003e, \u003cb\u003elowest price\u003c\/b\u003e, and \u003cb\u003eexpert support\u003c\/b\u003e to help you get the right product every time. \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007JES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 380,347V-120\/240V  50\/60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 50\/60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 380, 347\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Series (V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : None\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : None\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6A-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.63in\/448mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091460\u003c\/li\u003e\n\u003cli\u003eWeight : 170 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL, CE\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007JES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6A-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864321695,"sku":"C1F007JES-New","price":1645.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/hammond-power-solutions-transformer-new-c1f007jes-hammond-power-solutions-7-5-kva-347-380v-120-240v-encapsulated-potted-distribution-transformer-1-phase-nema-3r-53687839621279.jpg?v=1766010899"},{"product_id":"c1f007les","title":"Hammond Power Solutions C1F007LES - Transformer 7.5kVA 240x480V-120\/240V","description":" \t\t\t\t\t\t\t\t\t\t\u003ch2\u003eC1F007LES\u003c\/h2\u003e                                         \u003cbr\u003e \t\t\t\t\t\t\t\t\t\tHammond Power Solutions C1F007LES is a single-phase general duty transformer designed for industrial power distribution applications. This 7.5 kVA transformer features versatile voltage configurations with primary voltage of 240x480V and secondary voltage of 120\/240V, operating at 60Hz frequency with aluminum windings rated for 135Â°C temperature rise and 180Â°C insulation class. The unit is housed in a Type 3R\/IP24 enclosure with ANSI 61 Grey finish, measuring 17.63 inches in height, 12.25 inches in width, and 9.25 inches in depth, and operates at a quiet 45dBA sound level. It complies with IBC 2018 seismic standards (Sds=2.0, z\/h=1, lp=1.5) and features NEMA ST-20 construction with standard impedance ranging from 1% to 5%. Typical applications include industrial control systems, machinery power supplies, and commercial electrical distribution where reliable voltage transformation is required.      \u003cb\u003eKey Features \u0026amp; Specifications\u003c\/b\u003e  \u003cul\u003e \u003cli\u003eType: Single-Phase General Duty Transformer\u003c\/li\u003e \u003cli\u003eVoltage: Primary 240x480V, Secondary 120\/240V\u003c\/li\u003e \u003cli\u003eCurrent: 7.5 kVA Capacity\u003c\/li\u003e \u003cli\u003eFrequency: 60Hz\u003c\/li\u003e \u003cli\u003eMaterial: Aluminum Windings\u003c\/li\u003e \u003cli\u003eTemperature Rise: 135Â°C\u003c\/li\u003e \u003cli\u003eInsulation Class: 180Â°C\u003c\/li\u003e \u003cli\u003eEnclosure: Type 3R\/IP24, ANSI 61 Grey\u003c\/li\u003e \u003cli\u003eDimensions: 17.63\" H x 12.25\" W x 9.25\" D\u003c\/li\u003e \u003cli\u003eSound Level: 45dBA (NEMA ST-20)\u003c\/li\u003e \u003cli\u003eImpedance: 1% - 5% Standard\u003c\/li\u003e \u003cli\u003eSeismic Compliance: IBC 2018 (Sds=2.0)\u003c\/li\u003e \u003c\/ul\u003e \t\t\t\t\t\t\t\t\t\t\u003cbr\u003e                                          \t\t\t\t\t\t\t\t\t\t\u003ch3\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/h3\u003e \t\t\t\t\t\t\t\t\t\t\u003cul\u003e \t\t\t\t\t\t\t\t\t\t\t\u003cli\u003ePart Number: C1F007LES\u003c\/li\u003e                                             \u003cli\u003eManufacturer : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eBrand : Hammond Power Solutions\u003c\/li\u003e\n\u003cli\u003eCategory : Transformer\u003c\/li\u003e\n\u003cli\u003ePhase : 1\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade : Standard\u003c\/li\u003e\n\u003cli\u003eFortress : 1ph 7.5kVA 240x480V-120\/240V 60Hz AL\u003c\/li\u003e\n\u003cli\u003eDuty : General Duty\u003c\/li\u003e\n\u003cli\u003eFrequency : 60Hz\u003c\/li\u003e\n\u003cli\u003ePrimary Voltage : 240x480\u003c\/li\u003e\n\u003cli\u003ePrimary Connection : Parallel x Series (Vx2V)\u003c\/li\u003e\n\u003cli\u003ePrimary FCAN (NPL) : 2x2.5%\u003c\/li\u003e\n\u003cli\u003ePrimary FCBN (NPL) : 4x2.5%\u003c\/li\u003e\n\u003cli\u003eSecondary Voltage : 120\/240\u003c\/li\u003e\n\u003cli\u003eSecondary Connection : Parallel\/Series-N (V\/2V)\u003c\/li\u003e\n\u003cli\u003eMaterial : Aluminum\u003c\/li\u003e\n\u003cli\u003eTemperature Rise : 135Â°C\u003c\/li\u003e\n\u003cli\u003eInsulation Class : 180Â°C\u003c\/li\u003e\n\u003cli\u003eEKVA : 7.5\u003c\/li\u003e\n\u003cli\u003eEfficiency Regulation : No Efficiency Specification\u003c\/li\u003e\n\u003cli\u003eSeismic Compliance : IBC 2018 (Sds=2.0, z\/h=1, lp=1.5)\u003c\/li\u003e\n\u003cli\u003eSound Level : 45dBA (NEMA ST-20)\u003c\/li\u003e\n\u003cli\u003eImpedance (Std) : 1% - 5%\u003c\/li\u003e\n\u003cli\u003eSecondary Termination (NPL) : Mounting Pads\u003c\/li\u003e\n\u003cli\u003eEnclosure Type : Type 3R \/ IP24\u003c\/li\u003e\n\u003cli\u003eEnclosure Finish : ANSI 61 Grey, UL50\u003c\/li\u003e\n\u003cli\u003eEnclosure PN (NPL) : NQ6A-N3R\u003c\/li\u003e\n\u003cli\u003eEnclosure Dimensions : 17.63in\/448mm(H), 12.25in\/312mm(W), 9.25in\/235mm(D)\u003c\/li\u003e\n\u003cli\u003eElectrostatic Shield : Single\u003c\/li\u003e\n\u003cli\u003eNameplate : Standard\u003c\/li\u003e\n\u003cli\u003eStandard kVA : 7.5\u003c\/li\u003e\n\u003cli\u003eVector Configuration : 0Â°\u003c\/li\u003e\n\u003cli\u003eSeismic Standard Value : IBC 2018\u003c\/li\u003e\n\u003cli\u003eOSHPD : No\u003c\/li\u003e\n\u003cli\u003eSeismic IP : lp=1.5\u003c\/li\u003e\n\u003cli\u003eSeismic ZH : z\/h=1\u003c\/li\u003e\n\u003cli\u003eSeismic SDS Value : Sds=2.0\u003c\/li\u003e\n\u003cli\u003eEnclosure IR Window : No\u003c\/li\u003e \t\t\t\t\t\t\t\t\t\t\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eProduct Data\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUPC : 803423091361\u003c\/li\u003e\n\u003cli\u003eGTIN : 00803423091361\u003c\/li\u003e\n\u003cli\u003eWeight : 155 \u003c\/li\u003e\n\u003cli\u003eCertification : CSA, UL\u003c\/li\u003e\n\u003c\/ul\u003e                                         \u003cbr\u003e                                         \u003ch3\u003e\u003cb\u003eDocumentation and Resources\u003c\/b\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/info\/en\/pn\/C1F007LES\" target=\"_blank\"\u003eEngineering Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/documents.hammondpowersolutions.com\/documents\/Literature\/Low_Voltage_Distribution_(Encapsulated_and_Ventilated)_Brochures\/HPS-Fortress-Encapsulated-Transformers-For-Commercial-Applications-Brochure.pdf\" target=\"_blank\"\u003eBrochure \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/@HammondPowerSolutionsIncHPS\/videos\" target=\"_blank\"\u003eHammond Product Application Videos \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/americas.hammondpowersolutions.com\/resources\/\" target=\"_blank\"\u003eFrequently Asked Questions \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/www.hammondpowersolutions.com\/en\/Resources\/categories\/troubleshooting\/\" target=\"_blank\"\u003eTroubleshooting Guide \u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/engprd01.hammondpowersolutions.com\/encl\/pn\/NQ6A-N3R\/pdf\" target=\"_blank\"\u003eEnclosure CAD Drawing (PDF) \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e ","brand":"Hammond Power Solutions","offers":[{"title":"New","offer_id":62208864354463,"sku":"C1F007LES-New","price":1336.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0500\/2349\/7887\/files\/C1F007LES_1.jpg?v=1757541020"}],"url":"https:\/\/essentialparts.com\/collections\/hammond-freight.oembed","provider":"Essential Electric Supply","version":"1.0","type":"link"}